m+Medelevator.RU
← Поиск публикаций
Journal of bronchology & interventional pulmonology · 2026

Approaches for Lung Fiducial Markers Insertion in Stereotactic Body Radiotherapy: A Systematic Review and Meta-Analysis.

СтатьяСистематический обзорМетаанализНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Abellan Christophe, Mouraux Stéphane, Janett Simone, von Garnier Christophe, Villard Nicolas, Bongard Cédric, Kinj Remy, Bernasconi Maurizio, Treglia Giorgio, Valenti Antonio, Cappio Stefano, Martucci Francesco, Lovis Alban, Casutt Alessio

Аннотация

BACKGROUND: Pulmonary fiducial markers (FMs) allow real-time tracking for stereotactic body radiotherapy (SBRT) by CyberKnife, which is an alternative to surgery in early-stage inoperable non-small-cell lung cancer (NSCLC) or intrathoracic oligometastatic disease. We conducted a systematic review and meta-analysis to compare the clinical performance and safety of 3 available approaches for FMs insertion for peripheral pulmonary lesions (PPL): transthoracic, endovascular, and endobronchial accesses.

METHODS: A systematic review with meta-analysis was performed by searching PubMed/MEDLINE and EMBASE databases for all articles on FM implantation before SBRT. Outcomes included clinical performance (inaccurate FM location and tracking rate) and per-procedural complications (pneumothorax and hemoptysis). We included 27 studies for a total of 2065 patients (627 with endobronchial access, 993 with transthoracic access, and 445 with endovascular access) and 4149 FMs insertions.

RESULTS: The lowest inaccurate FM location rate was found with nonlinear FM inserted by endobronchial access (0.030, 95% CI: 0.004-0.074). Tracking rate was high and similar with endobronchial (0.975, 95% CI: 0.949-0.994), endovascular (0.999, 95% CI: 0.941-1.000), and transthoracic approaches (0.985, 95% CI: 0.963-0.998). The highest rates of pneumothorax (0.342, 95% CI: 0.261-0.427) and hemoptysis (0.035, 95% CI: 0.015-0.060) occurred with the transthoracic access.

CONCLUSION: While nonlinear FM insertion through endobronchial access achieved the lowest rate of inaccurate FM location, all 3 implantation approaches demonstrated high tracking feasibility for SBRT delivered using the CyberKnife system.

Предметные рубрики MeSH