Diagnostic performance of the Sofia® influenza A+B fluorescent immunoassay in adult outpatients in Northern Taiwan.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Jeng-How, Huang Po-Yen, Shie Shian-Sen, Yang Shuan, Tsao Kuo-Chien, Wu Tsu-Lan, Wu Ting-Shu, Huang Ching-Tai

Аннотация

To evaluate the diagnostic performance of the Sofia influenza A+B fluorescent immunoassay (Sofia FIA), we performed a prospective study at the Chang Gung Memorial Hospital in Taiwan from January 2012 to December 2013. Patients who presented at out-patient clinics or the emergency department with influenza-like illness were included. Upper respiratory tract specimens were collected from oropharynx or nasopharynx. Performance of the Sofia FIA was compared to that of the Formosa One Sure Flu A/B Rapid Test. A Real-time reverse transcriptase-polymerase chain reaction assay (RT-PCR) and/or virus culture were used as reference standards. Of the 109 enrolled patients, the sensitivity, specificity, positive, and negative predictive values of the Sofia FIA to detect influenza A virus were 82%, 89%, 77%, and 89%, respectively. These parameters were 100% when the samples were from nasopharynx. The positive predictive value for influenza B virus detection was 29%. The sensitivity of the Sofia FIA for detection of influenza A virus was 93% between days 2 and 4 after onset of symptoms. For specimens with low viral loads (RT-PCR cycle threshold between 30 and 34.9), the sensitivity of The Sofia FIA was 83% (10/12). The Sofia FIA performed effectively in detecting influenza A virus infection. With nasopharyngeal samples, the performance was comparable to RT-PCR. Although influenza viral load typically decreases with time, the Sofia FIA was sensitive enough to identify influenza infecting patients presenting after several days of illness. However, a high false positive rate limits the assay's usefulness to identify influenza B virus infection.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты