Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2017
Multi-center evaluation of the cobas® Liat® Influenza A/B & RSV assay for rapid point of care diagnosis.
Оценочное исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gibson Jane, Schechter-Perkins Elissa M, Mitchell Patricia, Mace Sharon, Tian Yu, Williams Kemi, Luo Robert, Yen-Lieberman Belinda
Аннотация
Point of Care Testing (POCT) provides the capability for rapid laboratory test results in patient care environments where a traditional clinical laboratory is not available. POCTs have shorter turn-around times (TATs), they may be performed by non-laboratory personnel, and the need for transport time is eliminated. The Food and Drug Administration (FDA) recently granted Clinical Laboratory Improvements Amendment (CLIA) waiver status to the cobas® Influenza A/B & RSV assay, a rapid, accurate point-of-care test for Influenza and respiratory syncytial virus (RSV) performed on the Liat® System. The performance characteristics of this test were determined though a multi-site study consisting of different point of care testing environments. Prospectively collected Nasopharyngeal (NP) swabs from 1361 patients seen at 8 primary care clinics and 4 emergency departments (EDs) and 295 retrospectively identified specimens were tested for Influenza A/B and RSV on the cobas® Liat® platform. Performance characteristics were determined through comparison to ProFlu+, a laboratory-based PCR test for Influenza A/B and RSV (reference test). Discordant specimens were adjudicated following bi-directional sequencing. The cobas® Influenza A/B and RSV assay showed sensitivities of 99.6%, 99.3%, and 96.8% for Influenza A, Influenza B, and RSV, respectively as determined from percent positive agreement (PPA) following comparison to the reference test. Sequencing confirmed cobas® Influenza A/B and RSV results in 49.2% of reference test discordant specimens, while crossing threshold data suggest increased sensitivity compared to the reference test. The cobas® Influenza A/B and RSV assay was found to be a rapid, sensitive POCT for the detection of these viruses, and provides laboratory-quality PCR-based diagnostic results in point of care settings.
Предметные рубрики MeSH
AdolescentAdultAgedChildFemaleHumansInfluenza A virusInfluenza B virusInfluenza, HumanMaleMiddle AgedMolecular Diagnostic TechniquesNasopharynxPoint-of-Care SystemsPolymerase Chain ReactionRespiratory Syncytial Virus InfectionsRespiratory Syncytial Virus, HumanRetrospective StudiesSensitivity and SpecificityUnited StatesYoung Adult