MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2014

Clinical application of catalytically cleavable fluorescence probe technology for multiplexing quantification of BCR-ABL1 fusion transcripts.

Park Kyoung-Jin, Woo Young Min, Kim Kwangwoo, Lee Seung-Tae, Ki Chang-Seok, Kim Hee-Jin, Kim Sun-Hee, Kim Jong-Won

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Accurate measurement of BCR-ABL1 fusion transcripts is critical for therapeutic stratification in patients with chronic myelogenous leukemia (CML). Previous studies have reported the variable performance of the existing quantitative reverse transcription polymerase chain reaction (RQ-PCR). Here, we developed a one-step multiplex RQ-PCR method based on the catalytically cleavable fluorescence probe technology for quantification of BCR-ABL1 transcripts.

METHODS

Performance was evaluated with respect to the limit of detection (LoD), linearity, precision, and comparison on the VIIA7 Real-Time PCR system. Multiplex RQ-PCR was performed by the one-step and one-well reaction without the hands-on time.

RESULTS

Our assay showed a LoD of 1.5 pg with linearity in the range of more than 4 logs of dilution. Intraassay, interassay, and total percent CVs at the concentration of 150 ng were 12.8%, 22.6%, and 28.0%, respectively. The assay correlated well with Asuragen's BCR/ABL1 Quant™ kit over a 6 log concentration range (r=0.9967).

CONCLUSION

Our assay demonstrated comparable performance characteristics in comparison with previous RQ-PCR based on the TaqMan probe technology.We conclude that our method could be a reliable tool in the clinical setting.

Для цитирования: Park Kyoung-Jin, Woo Young Min, Kim Kwangwoo, Lee Seung-Tae, Ki Chang-Seok, Kim Hee-Jin, Kim Sun-Hee, Kim Jong-Won. Clinical application of catalytically cleavable fluorescence probe technology for multiplexing quantification of BCR-ABL1 fusion transcripts.. Clinica chimica acta; international journal of clinical chemistry. 2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.