The British journal of surgery · 2004
Long-term effect of fundoplication on motility of the oesophagus and oesophagogastric junction.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Scheffer R C H, Samsom M, Frakking T G, Smout A J P M, Gooszen H G
Аннотация
BACKGROUND: This study assessed the long-term effect of Nissen fundoplication on oesophageal and oesophagogastric junction (OGJ) motility.
METHODS: Symptoms were scored and oesophageal manometry performed in 34 consecutive patients with chronic gastro-oesophageal reflux disease, before, 3 months after and 2 years after surgery.
RESULTS: Distal peristaltic amplitude increased from a median of 57 (95 per cent confidence interval (c.i.) 18 to 107) mmHg to 86 (95 per cent c.i. 54 to 208) mmHg (P < 0.001) at 3 months and 92 (45 to 210) mmHg (P < 0.001) at 2 years. In four patients the amplitude increased to more than 180 mmHg and three of these patients reported odynophagia. After surgery, a linear relationship was observed between the peristaltic amplitude and nadir OGJ relaxation pressure at 3 months (r(s) = 0.68, P < 0.001) and 2 years (r(s) = 0.64, P < 0.001). A significant correlation was also found between amplitude and both basal OGJ pressure and intrabolus pressure at 3 months (r(s) = 0.58, P < 0.001 and r(s) = 0.63, P < 0.001 respectively) and 2 years (r(s) = 0.71, P < 0.001 and r(s) = 0.49, P = 0.024). There was a relationship between peristaltic amplitude and the odynophagia score at 2 years (r(s) = 0.60, P = 0.017).
CONCLUSION: Within 3 months of fundoplication the amplitude of oesophageal peristalsis increased substantially, leading to a nutcracker oesophagus and odynophagia in a subgroup of patients. These phenomena did not appear to progress with time.
METHODS: Symptoms were scored and oesophageal manometry performed in 34 consecutive patients with chronic gastro-oesophageal reflux disease, before, 3 months after and 2 years after surgery.
RESULTS: Distal peristaltic amplitude increased from a median of 57 (95 per cent confidence interval (c.i.) 18 to 107) mmHg to 86 (95 per cent c.i. 54 to 208) mmHg (P < 0.001) at 3 months and 92 (45 to 210) mmHg (P < 0.001) at 2 years. In four patients the amplitude increased to more than 180 mmHg and three of these patients reported odynophagia. After surgery, a linear relationship was observed between the peristaltic amplitude and nadir OGJ relaxation pressure at 3 months (r(s) = 0.68, P < 0.001) and 2 years (r(s) = 0.64, P < 0.001). A significant correlation was also found between amplitude and both basal OGJ pressure and intrabolus pressure at 3 months (r(s) = 0.58, P < 0.001 and r(s) = 0.63, P < 0.001 respectively) and 2 years (r(s) = 0.71, P < 0.001 and r(s) = 0.49, P = 0.024). There was a relationship between peristaltic amplitude and the odynophagia score at 2 years (r(s) = 0.60, P = 0.017).
CONCLUSION: Within 3 months of fundoplication the amplitude of oesophageal peristalsis increased substantially, leading to a nutcracker oesophagus and odynophagia in a subgroup of patients. These phenomena did not appear to progress with time.