MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archoto.2009.170

Медицинская библиотека · Archives of otolaryngology--head & neck surgery · 2010

Reproducibility of clinical grading of tonsillar size.

Ng Siu Kwan, Lee Dennis Lip Yen, Li Albert Martin, Wing Yun Kwok, Tong Michael Chi Fai

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the reproducibility of the Brodsky grading scale and the modified 3-grade and 5-grade scales in reporting the size of the tonsils.

DESIGN

Retrospective review of 60 video recordings of tonsil examination by 12 independent observers with different clinical backgrounds and various levels of training. The sizes of the tonsils were graded using different grading scales.

SETTING

Tertiary care university hospital.

PARTICIPANTS

The video recordings were chosen from an ongoing epidemiologic study of sleep-related breathing disorder in children in Hong Kong. Main Outcomes Measures The intraobserver and interobserver reproducibility of each grading scale was determined using intraclass correlation. An intraclass correlation coefficient (ICC) exceeding 0.75 was set a priori to indicate an acceptable level of reliability.

RESULTS

The mean intraobserver ICCs for the Brodsky grading scale and the modified 3-grade and 5-grade scales were 0.858, 0.830, and 0.865, respectively. The mean interobserver ICCs for the Brodsky grading scale and the modified 3-grade and 5-grade scales were 0.763, 0.739, and 0.783, respectively.

CONCLUSION

The Brodsky grading scale and the modified 5-grade scale achieved acceptable intraobserver and interobserver reproducibility.

Для цитирования: Ng Siu Kwan, Lee Dennis Lip Yen, Li Albert Martin, Wing Yun Kwok, Tong Michael Chi Fai. Reproducibility of clinical grading of tonsillar size.. Archives of otolaryngology--head & neck surgery. 2010. DOI: 10.1001/archoto.2009.170.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.