MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4142/jvs.25125

Медицинская библиотека · Journal of veterinary science · 2025

Genetic resistance to vector-borne hemoprotozoa in livestock: molecular markers, host-parasite interactions, and implications for breeding and control.

Han Hyun Jin, Park Keun Young, Kim Byung Moon, Kim Yong Bae, Jeon Hong-Jun, Suh Sang Hyun, Suh Sangil, Kim Jung-Jae, Kim Jun-Hwee, Jang Chang Ki, Kim Dong Joon, Lee Jung Keun, Kim Sunghan, Chung Kyu Seon, Kim Solbi, Yoon Sun, Kim Min Jeoung

СтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVE

We evaluated the safety and efficacy of a new flow diverter in the treatment of unruptured wide-neck aneurysms.

MATERIALS AND

METHODS

Patients who had unruptured intracranial aneurysms with a neck diameter ≥4 mm or dome-to-neck ratio <2 and who met other eligibility criteria were enrolled from seven institutions. The patients were treated with a new flow diverter (FloWise; Taewoong Medical, Seoul, Korea) and followed at 1, 3, 6, and 12 months after treatment. The primary efficacy endpoint was the complete occlusion of the target aneurysm at 12 months. Safety endpoints included ipsilateral stroke (National Institutes of Health Stroke Scale score ≥5), newly developed neurological deficit (modified Rankin Scale score ≥3), death at 30 days, and ≥50% parent artery stenosis or occlusion at the 12-month follow-up. The superiority of FloWise over the predefined reference value (56.7%) was investigated using a one-sided binomial test with a statistical significance of P < 0.025.

RESULTS

Seventy patients (59.0 ± 9.9 years; male:female = 16:54) with 93 aneurysms (median diameter, 5.2 mm [range, 1.6-26.1 mm]; median neck diameter, 4.1 mm [range, 1.2-22.4 mm]) were included. Of these, 69 patients who completed the follow-up as planned constituted the efficacy analysis set. Complete aneurysm occlusion was achieved in 56 target aneurysms (81.2%; 95% confidence interval [CI], 69.9-89.6; P < 0.001). Procedural success and ≥50% aneurysm volume reduction were observed in 69 (100%) and 66 (95.7%; 95% CI, 87.8-99.1) target aneurysms, respectively. No ipsilateral strokes occurred in any of the 70 patients. Serious adverse events occurred in 6 patients; these events were causally related to the treatment in 4 (5.7%) cases and possibly related to the device in 2 (2.9%) cases.

CONCLUSION

FloWise flow diverter is safe and effective for the treatment of unruptured wide-neck aneurysms.

Для цитирования: Han Hyun Jin, Park Keun Young, Kim Byung Moon, Kim Yong Bae, Jeon Hong-Jun, Suh Sang Hyun, Suh Sangil, Kim Jung-Jae, Kim Jun-Hwee, Jang Chang Ki, Kim Dong Joon, Lee Jung Keun, Kim Sunghan, Chung Kyu Seon, Kim Solbi, Yoon Sun, Kim Min Jeoung. Genetic resistance to vector-borne hemoprotozoa in livestock: molecular markers, host-parasite interactions, and implications for breeding and control.. Journal of veterinary science. 2025. DOI: 10.4142/jvs.25125.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.