MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2012.11.039

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2013

Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.

Sauerbier Sebastian, Duttenhoefer Fabian, Sachlos Elefterios, Haberstroh Jörg, Scheifele Christian, Wrbas Karl-Thomas, Voss Pit Jacob, Veigel Egle, Smedek Jörg, Ganter Philip, Tuna Taskin, Gutwald Ralf, Palmowski Moritz

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Over the last decade tissue engineering has emerged as a key factor in bone regeneration within the field of cranio-maxillofacial surgery. Despite this in vivo analysis of tissue-engineered-constructs to monitor bone rehabilitation are difficult to conduct. Novel high-resolving flat-panel based volume CTs (fp-VCT) are increasingly used for imaging bone structures. This study compares the potential value of novel fp-VCT with conventional multidetector CT (MDCT) based on a sheep sinus floor elevation model. Calcium-hydroxyapatite reinforced collagen scaffolds were populated with autologous osteoblasts and implanted into sheep maxillary sinus. After 8, 16 and 24 weeks MDCT and fp-VCT scans were performed to investigate the volume of the augmented area; densities of cancellous and compact bone were assessed as comparative values. fp-VCT imaging resulted in higher spatial resolution, which was advantageous when separating closely related anatomical structures (i.e. trabecular and compact bone, biomaterials). Fp-VCT facilitated imaging of alterations occurring in test specimens over time. fp-VCTs therefore displayed high volume coverage, dynamic imaging potential and superior performance when investigating superfine bone structures and bone remodelling of biomaterials. Thus, fp-VCTs may be a suitable instrument for intraoperative imaging and future in vivo tissue-engineering studies.

Для цитирования: Sauerbier Sebastian, Duttenhoefer Fabian, Sachlos Elefterios, Haberstroh Jörg, Scheifele Christian, Wrbas Karl-Thomas, Voss Pit Jacob, Veigel Egle, Smedek Jörg, Ganter Philip, Tuna Taskin, Gutwald Ralf, Palmowski Moritz. Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2013. DOI: 10.1016/j.jcms.2012.11.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.