Technical feasibility of visualizing myenteric plexus using confocal laser endomicroscopy.

Kobayashi Masakuni, Sumiyama Kazuki, Shimojima Naoki, Ieiri Satoshi, Okano Hideyuki, Kamba Shunsuke, Fujimura Takumi, Hirobe Seiichi, Kuroda Tatsuo, Takahashi-Fujigasaki Junko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: In preceding studies, we identified that the myenteric plexus (MP) could be visualized with confocal laser endomicroscopy (CLE) by applying neural fluorescent probes lacking clinical safety profiling data from the submucosal side. In this study, we evaluated the technical feasibility of MP visualization using probe-based CLE (pCLE) from the serosal side with cresyl violet (CV), which has been used clinically for chromoendoscopy.

METHODS

The dye affinity of CV for MP was first explored in an in vivo transgenic mouse model using neural crest derivatives labeled with green fluorescent protein. We also tested the feasibility of CV-assisted visualization of MP in human surgical specimens, wherein the tissue dying and pCLE observation were performed from the serosal side. In the human study, rate of MP visualization by pCLE was evaluated as the primary outcome. We also evaluated the sensitivity and specificity of MP visualization by pCLE, using pathological presence/absence of MP as the gold standard.

RESULTS

We confirmed the dye affinity of CV to MP in all tested models. The MP appeared as brightly stained ladder-like structures with pCLE, and in the human study, MP was visualized in 12/14 (85.7%) samples, with 92.3% sensitivity and 100% specificity. In positive cases showing the ladder-like structure of MP by pCLE, the mean maximum and minimum widths of nerve strands were 54.3 (± 23.6) and 19.7 (± 6.0) μm, respectively. A ganglion was detected by pCLE in 10 cases (10/12, 83.3%).

CONCLUSIONS

This study demonstrated the technical feasibility of visualizing the MP in real time by CV-assisted pCLE (UMIN-CTR number, UMIN000015056).

Для цитирования: Kobayashi Masakuni, Sumiyama Kazuki, Shimojima Naoki, Ieiri Satoshi, Okano Hideyuki, Kamba Shunsuke, Fujimura Takumi, Hirobe Seiichi, Kuroda Tatsuo, Takahashi-Fujigasaki Junko. Technical feasibility of visualizing myenteric plexus using confocal laser endomicroscopy.. Journal of gastroenterology and hepatology. 2017. DOI: 10.1111/jgh.13754.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.