MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/spv.0000000000000461

Медицинская библиотека · Female pelvic medicine & reconstructive surgery · 2018

Surgical Anatomy of the Uterosacral Ligament Colpopexy.

Siff Lauren N, Jallad Karl, Hickman Lisa C, Walters Mark D

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to describe the relationship of the uterosacral ligament (USL) to the ureter and rectum along a surgeon's target location for suture placement under conditions simulating live surgery.

METHODS

Dissections were performed in 11 unembalmed female cadavers. Steps were taken to identify the USL simulating USL colpopexy. Pins were placed in the midportion of the USL at the level of the IS, and at 1-cm, 2-cm, and 3-cm increments traveling proximally toward the sacrum (Fig. 1). We measured minimum distances from the USL to the ureter and rectum at each target location.

RESULTS

In general, the ureters range from 1.3 to 2.0 cm lateral to the USLs along the target length. The rectum ranges from 1.9 to 2.6 cm from the right USL and remains 1.5 cm from the left USL. The mean change in distance between the ureter and USL for every 1 cm advanced toward the sacrum is 0.2 cm (95% confidence interval [CI], 0.19-0.24) on the right and 0.2 cm (95% CI, 0.18-0.27) on the left. The mean change in distance between the rectum and USL for every 1 cm advanced toward the sacrum is 0.2 cm (95% CI, 0.19-0.24) on the right and 0.0 cm (95% CI, 0-0) on the left.

CONCLUSIONS

For every centimeter traveled along the bilateral USLs from the IS toward the sacrum, the ureter moves 0.2 cm laterally away from the ligament, the rectum moves 0.2 cm medially away from the right USL, but maintains its position from the left USL.

Для цитирования: Siff Lauren N, Jallad Karl, Hickman Lisa C, Walters Mark D. Surgical Anatomy of the Uterosacral Ligament Colpopexy.. Female pelvic medicine & reconstructive surgery. 2018. DOI: 10.1097/spv.0000000000000461.