MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20220852

Медицинская библиотека · The British journal of radiology · 2023

Prostate stereotactic body radiotherapy: quantifying intra-fraction motion and calculating margins using the new BIR geometric uncertainties in daily online IGRT recommendations.

McNeice Joseph M, Sanilkumar Nandu, Alexander Sophie E, Talbot James, Tree Alison C, McNair Helen A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To measure the magnitude of intra-fraction prostate motion (IFPM) during stereotactic radiotherapy (SBRT) delivered without intra-fraction tracking.To assess if current margins adequately cover IFPM.To derive margins using new guidelines.

METHODS

IFPM was determined in 20 patients receiving 36.25 Gy in 5 fractions using 97 pairs of pre- and post-treatment cone beam CT (CBCT) scans. Correlation of time between CBCT acquisitions and motion was determined. The magnitude of IFPM was compared to current margins (6 mm isotropic, 3 mm posterior). Margins were calculated using IFPM alone and updated guidelines.

RESULTS

The averaged 3D root mean square IFPM was 2.5 mm (4.2 mm). Independent prostate motion was predominantly posterior (70%) and inferior (63%). There was weak correlation between posterior (ρ = 0.38) and inferior (ρ = 0.36) IFPM and time. IFPM greater than current margins occurred in 8 of 97 fractions, six in the posterior direction. Margins were ≤3.5 mm using IFPM alone and ≤3.3 mm Left 3.5 mm Right, 7.0 mm inferior, 3.7 mm superior, 4.4 mm anterior and 3.3 mm posterior using new guidelines, compensating for motion in 92% of fractions.

CONCLUSIONS

Our current SBRT margins account for 92% of IFPM, predominantly posterior and inferior. Although updated guidelines suggest an increase in margins inferiorly, any increase must be balanced against the possibility of increased toxicity, particularly if biochemical control and side-effects are favourable with current practice.

ADVANCES IN KNOWLEDGE: The difference between current clinical margins and those determined using updated guidance is demonstrated. The implications must be considered against clinical outcomes.

Для цитирования: McNeice Joseph M, Sanilkumar Nandu, Alexander Sophie E, Talbot James, Tree Alison C, McNair Helen A. Prostate stereotactic body radiotherapy: quantifying intra-fraction motion and calculating margins using the new BIR geometric uncertainties in daily online IGRT recommendations.. The British journal of radiology. 2023. DOI: 10.1259/bjr.20220852.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.