MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1121/1.5008741

Медицинская библиотека · The Journal of the Acoustical Society of America · 2017

The effects of varying tympanic-membrane material properties on human middle-ear sound transmission in a three-dimensional finite-element model.

O'Connor Kevin N, Cai Hongxue, Puria Sunil

СтатьяПоддержка NIH: внешняя программаВалидационное исследованиеПеревод пока не подготовлен

Аннотация

An anatomically based three-dimensional finite-element human middle-ear (ME) model is used to test the sensitivity of ME sound transmission to tympanic-membrane (TM) material properties. The baseline properties produce responses comparable to published measurements of ear-canal input impedance and power reflectance, stapes velocity normalized by ear-canal pressure (PEC), and middle-ear pressure gain (MEG), i.e., cochlear-vestibule pressure (PV) normalized by PEC. The mass, Young's modulus (ETM), and shear modulus (GTM) of the TM are varied, independently and in combination, over a wide range of values, with soft and bony TM-annulus boundary conditions. MEG is recomputed and plotted for each case, along with summaries of the magnitude and group-delay deviations from the baseline over low (below 0.75 kHz), mid (0.75-5 kHz), and high (above 5 kHz) frequencies. The MEG magnitude varies inversely with increasing TM mass at high frequencies. Increasing ETM boosts high frequencies and attenuates low and mid frequencies, especially with a bony TM annulus and when GTM varies in proportion to ETM, as for an isotropic material. Increasing GTM on its own attenuates low and mid frequencies and boosts high frequencies. The sensitivity of MEG to TM material properties has implications for model development and the interpretation of experimental observations.

Для цитирования: O'Connor Kevin N, Cai Hongxue, Puria Sunil. The effects of varying tympanic-membrane material properties on human middle-ear sound transmission in a three-dimensional finite-element model.. The Journal of the Acoustical Society of America. 2017. DOI: 10.1121/1.5008741.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.