Sudden onset of static equilibrium dysfunction in patients receiving a cochlear implant.

Gao Ying, Zhang Qing, Yan Jing, Niu Xiaorong, Han Peng, Yuan Haifeng, Hu Juan, Liu Bo, Xu Min

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We investigated the sudden onset of static equilibrium dysfunction caused by cochlear implantation (CI) in congenital hearing loss patients.

METHOD: Twenty-five patients were selected from a cohort of unilateral CI recipients to form the CI group. Static posturography was performed 1 to 3 days before and 3 to 5 days after CI. Each patient underwent the test with eyes open (EO) and eyes closed (EC) for 30 seconds, separately. Another group of age- and sex-matched patients with no history of hearing impairment undergoing unrelated surgeries formed the control group, and were examined with the same tests pre- and post-surgery. A third group of patients undergoing middle ear surgery formed the otitis media (OM) group. Postural sway parameters including sway velocity (SV) in the X-axis, SV in the Y-axis, length of sway locus length (LNG), and environmental area (ENV) were measured and recorded.

RESULTS

Comparison of pre-surgery posturographical parameters between the CI and control groups revealed no significant differences. Significant differences were found in most parameters in pre- and post-surgery comparisons in the CI group. Mean SV values in the X-axis pre- and post-surgery were 8.48 and 11.52 mm/s, respectively, in the EO condition (P < .05), and 14.94 and 20.16 mm/s, respectively, in the EC condition (P < .05). In the Y-axis, mean SV values were 15.36 and 20.24 mm/s pre- and post-surgery, respectively, in the EC condition (P < .05). The LNG values in the CI group pre- and post-surgery were 319.60 and 469.88 mm in the EO condition (P < .05), and 571.40 and 764.12 mm in the EC condition (P < .05). No significant functional equilibrium change was observed in the control group between pre- and post-surgery (P > .05) except SV in the X-axis and LNG in the EO condition (P < .05). No significant pre- and post-surgery differences were found in the OM group.

CONCLUSION

CI appeared to influence static equilibrium function within 1 week post-surgery. This influence was greater when eyes were closed.

Для цитирования: Gao Ying, Zhang Qing, Yan Jing, Niu Xiaorong, Han Peng, Yuan Haifeng, Hu Juan, Liu Bo, Xu Min. Sudden onset of static equilibrium dysfunction in patients receiving a cochlear implant.. Medicine. 2017. DOI: 10.1097/md.0000000000008465.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.