Membrane perforation in sinus floor elevation - piezoelectric device versus conventional rotary instruments for osteotomy: an experimental study.

Seoane Juan, López-Niño Javier, García-Caballero Lucía, Seoane-Romero Juan Manuel, Tomás Inmaculada, Varela-Centelles Pablo

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Sinus membrane perforation is the most common intraoperative complication of maxillary sinus floor elevation (MSFE) procedures and frequently causes postoperative problems. Piezoelectric devices have been claimed to reduce the frequency of membrane perforations although no clear evidence supports this view.

MATERIALS AND

METHODS

Ten surgeons with different expertise levels performed 80 MSFEs in selected lamb heads, with rotary and piezoelectric instruments following standard protocols. After the procedures, specimens were coded and perforations or tears determined through a microscope.

RESULTS

No significant differences in terms of thickness either of the sinus lateral wall (xi -xj  = 73.2; 95% confidence interval [CI] = 45.3-191.8) or the membrane (xi -xj  = 24.2; 95% CI = -29.4 to 77.9) were identified between the specimens allocated to each group. Nine membrane perforations (11.2%) occurred during the study, all within the lower expertise group. Membrane elevation by hand instruments caused five perforations (40%) in the rotary instrument group and one in the piezoelectric group. Expert surgeons produced no membrane perforations, the size of the antrostomy that was smaller in the piezoelectric group being the only significant difference between the rotary and piezoelectric groups.

CONCLUSIONS

The use of piezoelectric material for MSFE reduces the frequency of membrane perforation among surgeons with a limited experience.

Для цитирования: Seoane Juan, López-Niño Javier, García-Caballero Lucía, Seoane-Romero Juan Manuel, Tomás Inmaculada, Varela-Centelles Pablo. Membrane perforation in sinus floor elevation - piezoelectric device versus conventional rotary instruments for osteotomy: an experimental study.. Clinical implant dentistry and related research. 2012. DOI: 10.1111/j.1708-8208.2012.00447.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.