BACKGROUND

Techniques for endoscopic browlift include bony fixation over the lateral frontal region and soft tissue fixation over the temporal region. Although bony fixation over the lateral frontal region is advocated universally, limited information exists about bicortical thickness in this area.

OBJECTIVES

The authors provide bicortical thickness measurements between the frontal midline and the most inferior temporal region to assist surgeons in identifying appropriate fixation planes.

METHODS

Bicortical thickness was measured in the hemicraniums of 13 female cadavers, along the coronal planes that travel through the anterior border of the mandibular condyles and at the junction of the posterior mandibular condyles and the external auditory meatuses. Measurements began at the midline and coursed laterally at 1-cm intervals.

RESULTS

Average cranial thickness along the frontal region ranged from 8.9 ± 2.4 mm to 6.4 ± 2.8 mm over the anterior coronal line and 8.8 ± 2.2 mm to 5.6 ± 1.8 mm over the posterior line. Average thickness along the temporal region ranged from 5.6 ± 2.8 mm to 2.8 mm ± 1.4 mm over the anterior coronal line and 5.1 ± 1.8 mm to 3.4 ± 1.4 mm over the posterior line. Minimum thickness was 3.7 mm and 1.3 mm over the frontal and temporal regions, respectively. There was no significant difference between left and right hemicranial thickness.

CONCLUSIONS

To avoid violation of the inner cortex during surgery, endoscopic browlift procedures should include measurement of cortical thickness at various fixation points. Bony fixation over the temporal region should be avoided. Minimal bicortical thickness was observed in the lateral frontal region.

Для цитирования: Mowlavi Arian, Pham Sylvia, Lee Rolando, Huynh Peter, Wilhelmi Bradon. Cortical thickness parameters for endoscopic browlift fixation.. Aesthetic surgery journal. 2012. DOI: 10.1177/1090820x12445081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.