Vocal Fold Kinematics in Phonotrauma From High Speed Videoendoscopy.

Toles Laura E, Mau Ted

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVES

Phonotrauma is believed to result, in part, from elevated vocal fold contact stress associated with increased vocal fold closing speed and vocal hyperfunction. This study aimed to quantify vocal fold vibratory kinematics in phonotrauma, with the hypothesis that closing phase dynamics will be increased in individuals with phonotrauma.

METHODS

Twenty-six women with phonotraumatic vocal fold lesions and 29 vocally healthy control participants underwent high-speed videoendoscopy via a transoral rigid scope while phonating on a sustained /i/. Closing quotient (CQ), speed index (SI), amplitude-to-length ratio (ALR), stiffness index (STI), and maximum area declination rate (MADR) were compared between groups using independent t-tests and Cohen's d effect sizes.

RESULTS

Participants with phonotrauma had higher values of ALR (mean [SD], 11.5 [4.3] vs. 8.5 [2.3], p = 0.002, d = 0.86), indicating greater amplitude of vibration compared to controls. Similarly, the MADR was also higher in the phonotrauma group (mean [SD], 1.47 [1.05] vs. 0.51 [0.16] Mpx/s, p < 0.001, d = 1.3), indicating that the vocal fold closing speed was higher in the phonotrauma group. There was no difference in CQ, SI, or STI.

CONCLUSION

These data support the link between phonotraumatic lesions and increased vocal fold contact stress. The findings highlight the maladaptive hyperfunctional cycle that accompanies phonotraumatic lesions and the disruption to vocal efficiency in the setting of phonotrauma.

Для цитирования: Toles Laura E, Mau Ted. Vocal Fold Kinematics in Phonotrauma From High Speed Videoendoscopy.. The Laryngoscope. 2025. DOI: 10.1002/lary.32452.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.