Deep learning based time-dependent reliability analysis of an underactuated lower-limb robot exoskeleton for gait rehabilitation.

Hussain Fahad, Goyal Tanishka, Hussain Shahid, Jamwal Prashant, Goecke Roland

СтатьяПеревод пока не подготовлен

Аннотация

This study evaluates the reliability of an underactuated wearable lower-limb exoskeleton designed to assist with gait rehabilitation. Recognizing the complexity of system reliability, a deep learning framework augmented with Long short-term Memory (LSTM) was utilized for the time-dependent reliability analysis of dynamic systems. The research commenced with the development of a lower-limb gait robot, modeled on a Stephenson III six-bar linkage mechanism. Following the mechanical design, computer-aided design (CAD) tools were employed to conceptualize a lower-limb robotic exoskeleton for rehabilitation purposes. The design incorporated two metallic materials (aluminum and steel), and a composite material (carbon fiber) tested using SolidWorks®. The prototype achieved a lightweight design (~1.63 kg) for carbon fiber material. An LSTM-enhanced deep neural network algorithm was implemented to predict the time-dependent reliability of joint displacements and end-effector trajectories. Finally, conditional probability methods were applied to complete the time-dependent system reliability assessment. The designed mechanical system for gait rehabilitation demonstrated high reliability (R ≈ 0.87). Over 200 simulation runs, reliability trends showed consistent and robust predictions.

Для цитирования: Hussain Fahad, Goyal Tanishka, Hussain Shahid, Jamwal Prashant, Goecke Roland. Deep learning based time-dependent reliability analysis of an underactuated lower-limb robot exoskeleton for gait rehabilitation.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2025. DOI: 10.1177/09544119251349362.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.