PURPOSE: To evaluate adaptive planning for permanent prostate brachytherapy and to identify the prostate regions that needed adaptation.
METHODS AND MATERIALS: After the implantation of stranded seeds, using real-time intraoperative planning, a transrectal ultrasound (TRUS)-scan was obtained and contoured. The positions of seeds were determined on a C-arm cone-beam computed tomography (CBCT)-scan. The CBCT-scan was registered to the TRUS-scan using fiducial gold markers. If dose coverage on the combined image-dataset was inadequate, an intraoperative adaptation was performed by placing remedial seeds. CBCT-based intraoperative dosimetry was analyzed for the prostate (D90, V100, and V150) and the urethra (D30). The effects of the adaptive dosimetry procedure for Day 30 were separately assessed.
RESULTS: We analyzed 1266 patients. In 17.4% of the procedures, an adaptation was performed. Without the dose contribution of the adaptation Day 30 V100 would be < 95% for half of this group. On Day 0, the increase due to the adaptation was 11.8 ± 7.2% (1SD) for D90 and 9.0 ± 6.4% for V100. On Day 30, we observed an increase in D90 of 12.3 ± 6.0% and in V100 of 4.2 ± 4.3%. For the total group, a D90 of 119.6 ± 9.1% and V100 of 97.7 ± 2.5% was achieved. Most remedial seeds were placed anteriorly near the base of the prostate.
CONCLUSION: CBCT-based adaptive planning enables identification of implants needing adaptation and improves prostate dose coverage. Adaptations were predominantly performed near the anterior base of the prostate.
METHODS AND MATERIALS: After the implantation of stranded seeds, using real-time intraoperative planning, a transrectal ultrasound (TRUS)-scan was obtained and contoured. The positions of seeds were determined on a C-arm cone-beam computed tomography (CBCT)-scan. The CBCT-scan was registered to the TRUS-scan using fiducial gold markers. If dose coverage on the combined image-dataset was inadequate, an intraoperative adaptation was performed by placing remedial seeds. CBCT-based intraoperative dosimetry was analyzed for the prostate (D90, V100, and V150) and the urethra (D30). The effects of the adaptive dosimetry procedure for Day 30 were separately assessed.
RESULTS: We analyzed 1266 patients. In 17.4% of the procedures, an adaptation was performed. Without the dose contribution of the adaptation Day 30 V100 would be < 95% for half of this group. On Day 0, the increase due to the adaptation was 11.8 ± 7.2% (1SD) for D90 and 9.0 ± 6.4% for V100. On Day 30, we observed an increase in D90 of 12.3 ± 6.0% and in V100 of 4.2 ± 4.3%. For the total group, a D90 of 119.6 ± 9.1% and V100 of 97.7 ± 2.5% was achieved. Most remedial seeds were placed anteriorly near the base of the prostate.