OBJECTIVE

To characterize stimulation of taste fibers in the facial nerve following cochlear implantation.

PATIENT: A 34-year old presented with reversible dysgeusia following activation of a cochlear implant.

INTERVENTION: Reprogramming targeted to specific offending electrodes reduced symptom intensity. Computed tomography demonstrated dehiscence of the bone separating the labyrinthine segment of the facial nerve and the basal turn of the cochlea in proximity to the electrode array.

RESULTS

Dysgeusia was attributed to stimulation of taste fibers in the facial nerve by electrodes 13 to 16 of the cochlear implant array located in the superior-most portion of the basal turn.

CONCLUSIONS

Dysgeusia following cochlear implant activation has not previously been reported. This likely results from stimulation of taste fibers through dehiscence of the bone separating the labyrinthine segment of the Fallopian canal and the basal turn of the cochlea. While in some cases of apparent dehiscence there may be thin bone present, recognition of this potential anatomic feature may influence the choice of which ear and which electrode design to implant.

Для цитирования: Shayman Corey S, Middaugh Jessica L, Hullar Timothy E. Taste Disturbance Due to Cochlear Implant Stimulation.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2016. DOI: 10.1097/mao.0000000000001143.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.