MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_123_20

Медицинская библиотека · Indian journal of ophthalmology · 2020

Ocular structural changes in patients with Duane retraction syndrome: Does a correlation exist?

Kekunnaya Ramesh, Marella Bhagya L, Peguda Hari K, Sachdeva Virender

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The purpose of this study was to investigate the structural changes (axial length, central macular thickness (CMT), subfoveal choroidal thickness, and keratometry) in subjects with unilateral Duane retraction syndrome (DRS) as compared with the normal fellow eye.

METHODS

In this prospective study, we included 34 subjects with unilateral DRS from January 2016 to December 2016 seen at our institute. Data was collected for axial length, keratometry using partial coherence interferometry, CMT, subfoveal choroidal thickness using the enhanced depth imaging-optical coherence tomography (EDI-OCT). All these measurements were compared between the affected and fellow eye.

RESULTS

During this period, we included 34 subjects with unilateral DRS (22 Type I, 1 Type II, and 11 Type III). The mean age (±SD) of subjects was 14 ± 8 years (range: 5-28 years). There were 15 males and 19 females. Eyes with DRS were significantly shorter (median axial length 22.4 mm, interquartile range (IQR): 21.56 - 23.17) as compared to fellow eye (median axial length 22.7 mm, IQR: 22.35-23.55), P = 0.04. Choroidal thickness, CMT, and average keratometry were similar in DRS and fellow eyes (P = 0.39, 0.06, and 0.11, respectively). A significant difference in axial length was found only between Type I and Type III DRS (P = 0.03).

CONCLUSION

This study suggests that in subjects with DRS, the affected eye has shorter median axial length when compared with the fellow eye. Prevalence of refractive error in eye with DRS was higher compared to fellow eye. But, there was no difference in magnitude of refractive error found between eye with DRS and normal fellow eye.

Для цитирования: Kekunnaya Ramesh, Marella Bhagya L, Peguda Hari K, Sachdeva Virender. Ocular structural changes in patients with Duane retraction syndrome: Does a correlation exist?. Indian journal of ophthalmology. 2020. DOI: 10.4103/ijo.ijo_123_20.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.