Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2025

A qualitative, quantitative and dosimetric evaluation of a machine learning-based automatic segmentation method in treatment planning for gastric cancer.

СтатьяОценочное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mazonakis Michalis, Tzanis Eleftherios, Kachris Stefanos, Lyraraki Efrossyni, Damilakis John

Аннотация

PURPOSE: To investigate the performance of a machine learning-based segmentation method for treatment planning of gastric cancer.

MATERIALS AND METHODS: Eighteen patients planned to be irradiated for gastric cancer were studied. The target and the surrounding organs-at-risk (OARs) were manually delineated on CT scans. A machine learning algorithm was used for automatically segmenting the lungs, kidneys, liver, spleen and spinal cord. Two radiation oncologists evaluated these contours and performed the required editing. The accuracy of the auto-segmented contours relative to manual outlines was evaluated by calculating the dice similarity coefficient (DSC), Jaccard score (JS), sensitivity and precision. VMAT plans were initially created on manual contours (MCPlans) and, then, on edited and unedited auto-segmented contours (ACedPlans). Dose parameters of the OARs and target volume derived from the different treatment plans were statistically compared.

RESULTS: The 24.6 % of the auto-segmented contours were acceptable and 40.5 % needed changes related to stylistic deviations. Minor editing was applied in 34.1 % of these contours. The mean values of the DSC, JS, sensitivity and precision associated with the comparison of the manual outlines and the contour set including edited and unedited auto-segmented contours were 0.91-0.97, 0.84-0.94, 0.92-0.97 and 0.91-0.97, respectively. No significant differences were found for fifteen out of eighteen examined dosimetric parameters derived from MCPlans and ACedPlans (p > 0.05). These parameters from the MCPlans agreed well with those from ACedPlans based on the Bland-Altman test.

CONCLUSIONS: The qualitative, quantitative and dosimetric analysis highlighted the clinical acceptability of a machine learning-based segmentation method for radiotherapy of gastric cancer.