Shanghai kou qiang yi xue = Shanghai journal of stomatology · 2011
[Clinical use of beta-tricalcium phosphate ceramics with patient's own bone in maxillary elevation with osteotome].
Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chen Lu, Zhou Wen-qing, Wu Yan-ping, Lu Jing-hua
Аннотация
PURPOSE: To evaluate the clinical value of using the patient's autogenous bone mixed with beta-tricalcium phosphate ceramics(β-TCP) for maxillary sinus lift with simultaneous implantation.
METHODS: Patients with loss of posterior teeth and bone height of maxillary sinus floor between 4-10mm underwent internal sinus floor elevation, the proportion of bone to β-TCP was 1:1 and the mixture was inserted into the sinus floor. All cases had simultaneously placed ITI implants.The final crown fabrication was taken 4-6 months after implanting.
RESULTS: Twenty-one implants were inserted in 16 cases, the mean increase height was 4.2mm(2-6mm). There was clinical complaint of maxillary sinus inflammation in 1 case within 2 weeks, but the symptoms disappeared after antibiotic therapy. The remaining of 20 implants had no obvious complications. All implants had loaded for 32 months and were stable and well osseointegration on X-ray film.
CONCLUSIONS: Maxillary sinus elevation with simultaneous implantation is an easy procedure. Implants can be stable for a long time.
METHODS: Patients with loss of posterior teeth and bone height of maxillary sinus floor between 4-10mm underwent internal sinus floor elevation, the proportion of bone to β-TCP was 1:1 and the mixture was inserted into the sinus floor. All cases had simultaneously placed ITI implants.The final crown fabrication was taken 4-6 months after implanting.
RESULTS: Twenty-one implants were inserted in 16 cases, the mean increase height was 4.2mm(2-6mm). There was clinical complaint of maxillary sinus inflammation in 1 case within 2 weeks, but the symptoms disappeared after antibiotic therapy. The remaining of 20 implants had no obvious complications. All implants had loaded for 32 months and were stable and well osseointegration on X-ray film.
CONCLUSIONS: Maxillary sinus elevation with simultaneous implantation is an easy procedure. Implants can be stable for a long time.