MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joms.2010.10.033

Медицинская библиотека · Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons · 2011

Prevalence, location, and size of maxillary sinus septa: panoramic radiograph versus computed tomography scan.

Maestre-Ferrín Laura, Carrillo-García Celia, Galán-Gil Sónnica, Peñarrocha-Diago María, Peñarrocha-Diago Miguel

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the prevalence, location, and size of maxillary sinus septa, and to compare the results of panoramic radiographs and computed tomography (CT) scans.

MATERIALS AND

METHODS

This study included 30 patients, 17 women and 13 men, with a mean age of 50.9 years (range, 28-73 years), undergoing treatment planning for implant-supported restorations in the maxilla. Three observers analyzed the panoramic radiographs, the conventional CT scans in acetate, and the Implametric 3-dimensional CT (3Dent, Valencia, Spain). The maxillary sinus septa of each patient and the type of septa, as well as its location and size, were recorded.

RESULTS

In 60 maxillary sinuses, panoramic radiographs showed 32 septa (53.3%); CT in acetate showed 42 septa (70%); and Implametric 3-dimensional CT showed 40 septa (66.7%). Most septa (60%) were located in the middle region of the maxillary sinus, 22.5% in the posterior region, and 17.5% in the anterior region. The mean height of the septa was 4.78 ± 1.76 mm. Panoramic radiographs led to an erroneous diagnosis in 46.5% of the cases.

CONCLUSIONS

Maxillary sinus septa are a frequent anatomic variation. They can be found in any of the maxillary sinus regions independently of patient edentulism. The panoramic radiograph can lead to false-positive and false-negative findings in the visualization of septa in almost half of cases. Therefore, whenever a maxillary sinus lift is planned, a thorough study of the affected sinus should be made using CT.

Для цитирования: Maestre-Ferrín Laura, Carrillo-García Celia, Galán-Gil Sónnica, Peñarrocha-Diago María, Peñarrocha-Diago Miguel. Prevalence, location, and size of maxillary sinus septa: panoramic radiograph versus computed tomography scan.. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2011. DOI: 10.1016/j.joms.2010.10.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.