DOI 10.1016/j.resuscitation.2023.109741
The effect of hand position on chest compression quality during CPR in young children: Findings from the Videography in Pediatric Resuscitation (VIPER) collaborative.
Аннотация
OBJECTIVE
To determine the effect of hand position on chest compression (CC) quality during CPR in young children.
METHODS
Prospective observational exploratory study. Patients < 8 years receiving CC for > 2 minutes were enrolled. Data was collected from video review and CC monitor device and analyzed in 'CC segments' (periods of CC by individual providers). Four techniques were compared: two thumbs (2 T), hands encircling the chest; two fingers (2F) on the sternum; one hand on sternum (1H); two hands on sternum (2H). Univariate analysis of CC rate and depth between hand positions was performed through nonparametric testing, stratified by age category.
RESULTS
47 patients received 824 minutes of CC. Among 270 CC segments in infants < 1 yo, 2 T was used in 27%; 2F 3%; 1H 18%; 2H 26%. Among 189 CC segments in children aged 1 to 8 yo, 1H was used in 26%; 2H 74%. Across all segments, median CC rate was 117 cpm (IQR 110-125). Median depth was 2.92 cm (IQR 2.44 - 4.04) in infants < 1 yo, 3.56 cm (IQR 2.92 - 4.14) in children 1 to 8 yo. 1H achieved greater depth than 2 T in infants (p < 0.01), and 2H achieved greater depth than 1H in children > 1 (p < 0.001).
CONCLUSIONS
In infants, 1H resulted in greater CC depth than 2 T. In children 1 to 8 yo, 2H resulted in greater depth than 1H.. These data suggest that different hand position during CPR in young children from what is currently recommended may result in better CPR quality.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.