[Low temperature plasma minimally invasive treatment of children piriform fossa fistula].

Ji R F, Zhao Z L, Zhou Q, Meng Z X, Ji W

СтатьяПеревод в очереди

Аннотация

Objective

To observe the clinical efficacy of lowtemperature plasma minimally invasive treatment of piriform fossa fistula in children at the infection stage and non-infection stage. Method: Twenty-five pediatric patients of piriform fovea fistula were treated with low-temperature plasma minimally invasive treatment. These patients were divided into the infection stage group(16 cases) and the non-infection stage group(9 cases). In both groups, low-temperature plasma ablation was performed to close the piriform fossa fistula under laryngoscope supported by endotracheal intubation under general anesthesia. For patients in infection stage, simultaneous cervical abscess incision and drainage were performed. The efficacy, postoperative recurrence rate and complications of the two groups were compared. Result: In the non-infection stage group, 7 cases were cured by 1 operation, and 2 cases were cured by the reoperation. In the infection stage group, 10 cases were cured by 1 operation, 5 cases were cured by the reoperation, and 1 case was cured by external fistula resection due to repeated purulent discharge of neck infection. No recurrent laryngeal nerve injury, massive hemorrhage or other complications occurred in these patients.

Conclusion

Low temperature plasma minimally invasive treatment is safe and effective for pediatric patients of piriform fossa fistula.

Для цитирования: Ji R F, Zhao Z L, Zhou Q, Meng Z X, Ji W. [Low temperature plasma minimally invasive treatment of children piriform fossa fistula].. Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery. 2019. DOI: 10.13201/j.issn.1001-1781.2019.05.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.