DOI 10.1186/s13014-020-01515-5
Evaluating dosimetric constraints for carbon ion radiotherapy in the treatment of locally advanced pancreatic cancer.
Аннотация
OBJECTIVE
To identify a safe carbon ion radiotherapy (CIRT) regimen for patients with locally advanced pancreatic cancer (LAPC).
METHODS
We generated treatment plans for 13 consecutive, unselected patients who were treated for LAPC with CIRT at our center using three dose and fractionation schedules: 4.6 GyRBE × 12, 4.0 GyRBE × 14, and 3.0 GyRBE × 17. We tested the ability to meet published dose constraints for the duodenum, stomach, and small bowel as a function of dose schedule and distance between the tumor and organs at risk.
RESULTS
Using 4.6 GyRBE × 12 and 4.0 GyRBE × 14, critical (high-dose) constraints could only reliably be achieved when target volumes were not immediately adjacent to organs at risk. Critical constraints could be met in all cases using 3.0 GyRBE × 17. Low-dose constraints could not uniformly be achieved using any dose schedule.
CONCLUSION
While selected patients with LAPC may be treated safely with a CIRT regimen of 4.6 GyRBE × 12, our dosimetric analyses indicate that a more conservative schedule of 3.0 GyRBE × 17 may be required to safely treat a broader population of LAPC patients, including those with large tumors and tumors that approach gastrointestinal organs at risk. The result of this work was used to guide an ongoing clinical trial.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.