MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcjo.2025.03.012

Медицинская библиотека · Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2025

Surgical outcomes of small and medium macular holes with or without use of internal limiting membrane flaps.

Aizouki Carolin, Qiu Weilin, Loh Graeme K, Greve Mark D J, Tennant Matthew T S, Grewal Parampal S, Seamone Mark E, Mishra Amit V

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aims to evaluate the long-term visual and anatomical outcomes of the inverted flap technique in small-to-medium sized macular holes (MH).

DESIGN

Retrospective chart review.

PARTICIPANTS

Consecutive patients who underwent macular hole surgery at a single retina center in Alberta, Canada.

METHODS

Macular hole surgeries were stratified on the basis of size. Postsurgical visual outcomes and hole closure rates were captured. Large holes were excluded from analysis.

RESULTS

A total of 239 medium and 252 small holes were included; 65 medium and 40 small holes had internal limited membrane (ILM) flaps. In the small MH group, mean hole size was 170.7 μm, and visual gain averaged 6.4 ETDRS letters, with no significant difference based on surgical technique (p = 0.7). All small holes closed with ILM flapping with 4 (2%) of the ILM peels not closing, this was not significant (p = 0.4). In medium MH, mean hole size was 320.9 μm, and visual gain averaged 11.9 ETDRS letters, with no significant difference based on surgical technique (p = 0.5). All medium holes closed with ILM flapping, with 8 (5%) of the standard ILM peel not closing; this was not significant (p = 0.08).

CONCLUSIONS

There was no significant difference in either surgical closure rates or visual acuity gains when comparing ILM peeling to the flap technique for both small and medium-sized MH.

Для цитирования: Aizouki Carolin, Qiu Weilin, Loh Graeme K, Greve Mark D J, Tennant Matthew T S, Grewal Parampal S, Seamone Mark E, Mishra Amit V. Surgical outcomes of small and medium macular holes with or without use of internal limiting membrane flaps.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2025. DOI: 10.1016/j.jcjo.2025.03.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.