Performance and Interpretation of Hydrogen and Methane Breath Testing Impact of North American Consensus Guidelines.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pitcher Charlotte K, Farmer Adam D, Haworth Jordan J, Treadway Sam, Hobson Anthony R
Аннотация
BACKGROUND: Hydrogen and methane breath tests (HMBT) are widely used clinical investigations but lack standardization. To address this, the North American Consensus (NAC) group published evidence-based recommendations for HMBT.
AIMS: To evaluate results obtained using NAC recommendations for HMBT, compared to retrospective data that utilized guidelines previously recommended.
METHODS: HMBT data from 725 patients referred for small intestinal bacterial overgrowth (SIBO) and/or carbohydrate malabsorption (CM) testing were analyzed. Data were compared regarding dose of substrate for SIBO testing (16 vs. 10 g lactulose, and 50 vs. 75 g glucose) and the effect of post-ingestion sampling period for malabsorption testing. The effect of different recommended cut-off values for SIBO were examined.
RESULTS: Substrate dose did not affect methane production. 10 g lactulose significantly reduced positive SIBO results compared to 16 g lactulose (42 vs. 53%, p = 0.04). 75 g glucose significantly increased positive results compared to 50 g glucose (36 vs. 22%, p = 0.04). Provoked symptoms were significantly more prevalent in patients testing positive by both North American Consensus and Ledochowski cut-off values. 34.5% of patients tested positive for CM at 180-min compared to 28% at 120-min (not significant, p = 0.19).
CONCLUSIONS AND INFERENCES: 10 g lactulose substrate produces fewer positive SIBO results than 16 g lactulose, while 75 g glucose dose produces more positive SIBO results than 50 g. Performing CM breath tests for 180 min increases number of positive results when compared to 120 min. SIBO cut-off timings require further investigation, but our findings broadly support the NAC recommendations for SIBO and CM testing.
AIMS: To evaluate results obtained using NAC recommendations for HMBT, compared to retrospective data that utilized guidelines previously recommended.
METHODS: HMBT data from 725 patients referred for small intestinal bacterial overgrowth (SIBO) and/or carbohydrate malabsorption (CM) testing were analyzed. Data were compared regarding dose of substrate for SIBO testing (16 vs. 10 g lactulose, and 50 vs. 75 g glucose) and the effect of post-ingestion sampling period for malabsorption testing. The effect of different recommended cut-off values for SIBO were examined.
RESULTS: Substrate dose did not affect methane production. 10 g lactulose significantly reduced positive SIBO results compared to 16 g lactulose (42 vs. 53%, p = 0.04). 75 g glucose significantly increased positive results compared to 50 g glucose (36 vs. 22%, p = 0.04). Provoked symptoms were significantly more prevalent in patients testing positive by both North American Consensus and Ledochowski cut-off values. 34.5% of patients tested positive for CM at 180-min compared to 28% at 120-min (not significant, p = 0.19).
CONCLUSIONS AND INFERENCES: 10 g lactulose substrate produces fewer positive SIBO results than 16 g lactulose, while 75 g glucose dose produces more positive SIBO results than 50 g. Performing CM breath tests for 180 min increases number of positive results when compared to 120 min. SIBO cut-off timings require further investigation, but our findings broadly support the NAC recommendations for SIBO and CM testing.