Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?

Kim Seong-Hun, Kang Seok-Man, Choi Yong-Suk, Kook Yoon-Ah, Chung Kyu-Rhim, Huang John C

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

The purposes of this study were to determine factors favoring successful mini-implant placement and to evaluate root proximity as a possible risk factor for failure of osseointegration-based mini-implants during orthodontic treatment.

METHODS

Three-dimensional cone-beam computed tomography images were used to examine 50 sandblasted, large-grit, and acid-etched surface-treated mini-implants (C-implant, Seoul, Korea) placed in 25 patients. The images were analyzed for 3-dimensional position of the mini-implant (placement angle and depth) and any contact with root surfaces or maxillary sinuses.

RESULTS

There were no remarkable differences in horizontal placement angles in the axial plane and placement depths of the mini-implants, but the vertical placement angle was significantly higher on the left side (24.5 degrees +/- 11.0 degrees ) compared with the right side (11.8 degrees +/- 11.6 degrees ). The horizontal mini-implant placement angle had a greater inclination tendency toward the maxillary first molar, and 11 mini-implants with root proximity showed mesiobuccal contact with the maxillary first molar root. Only 1 failure in 15 mini-implants with root proximity and 1 failure in 35 without root proximity were observed on the images.

CONCLUSIONS

Root proximity alone was not considered a major risk factor for osseointegration-based mini-implant failure.

Для цитирования: Kim Seong-Hun, Kang Seok-Man, Choi Yong-Suk, Kook Yoon-Ah, Chung Kyu-Rhim, Huang John C. Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2010. DOI: 10.1016/j.ajodo.2008.07.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.