DOI 10.1111/j.1600-0501.2010.02066.x
Computer-aided design and manufacturing construction of a surgical template for craniofacial implant positioning to support a definitive nasal prosthesis.
Аннотация
AIM: To design a surgical template to guide the insertion of craniofacial implants for nasal prosthesis retention.
MATERIALS AND
METHODS
The planning of the implant position was obtained using software for virtual surgery; the positions were transferred to a free-form computer-aided design modeling software and used to design the surgical guides. A rapid prototyping system was used to 3D-print a three-part template: a helmet to support the others, a starting guide to mark the skin before flap elevation, and a surgical guide for bone drilling. An accuracy evaluation between the planned and the placed final position of each implant was carried out by measuring the inclination of the axis of the implant (angular deviation) and the position of the apex of the implant (deviation at apex).
RESULTS
The implant in the glabella differed in angulation by 7.78°, while the two implants in the premaxilla differed by 1.86 and 4.55°, respectively. The deviation values at the apex of the implants with respect to the planned position were 1.17 mm for the implant in the glabella and 2.81 and 3.39 mm, respectively, for those implanted in the maxilla.
CONCLUSIONS
The protocol presented in this article may represent a viable way to position craniofacial implants for supporting nasal prostheses.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.