MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-003-0106-y

Медицинская библиотека · Abdominal imaging · 2004

Use of thin-section, multidetector row helical CT images for coronal oblique reformations for optimal visualization of structures in the hepatoduodenal ligament.

Faria S C, Tamm E P, DuBrow R, David C, Loyer E, Herron D, Sawaf Y, Ball G, Silverman P M, Charnsangavej C

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Multidetector row computed tomography (CT) can acquire abdominal images of unprecedented thinness in a single breath-hold. This study investigated whether acquiring source axial images at 1.25 mm as opposed to 2.5 mm would result in a perceptible difference in image quality for coronal oblique reformations. Similarly, the hypothesis that a slice pitch of 3:1 would be superior to 6:1 was evaluated. Twenty-nine CT studies were retrospectively evaluated. The images were divided into four groups: 1.25-mm axial images, pitch 3:1; 2.5-mm axial images, pitch 3:1; 1.25-mm axial images, pitch 6:1; and 2.5-mm axial images, pitch 6:1. Three radiologists evaluated by consensus the coronal oblique reformations for overall image quality and image quality of structures in the hepatoduodenal ligament and of nodal groups. Use of 1.25-mm rather than of 2.5-mm source axial images resulted in statistically significant better scores for overall image quality and visualization of the hepatic artery, portal vein, pancreatic duct, and nodal groups. However, a pitch of 3:1 rather than of 6:1 did not result in significant differences in ratings of image quality. Use of 1.25-mm rather than of 2.5-mm source axial images improves image quality when creating coronal oblique reformations for abdominal anatomy.

Для цитирования: Faria S C, Tamm E P, DuBrow R, David C, Loyer E, Herron D, Sawaf Y, Ball G, Silverman P M, Charnsangavej C. Use of thin-section, multidetector row helical CT images for coronal oblique reformations for optimal visualization of structures in the hepatoduodenal ligament.. Abdominal imaging. 2004. DOI: 10.1007/s00261-003-0106-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.