MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005537-200402000-00022

Медицинская библиотека · The Laryngoscope · 2004

Complications of microdebrider-assisted powered intracapsular tonsillectomy and adenoidectomy.

Sorin Alexander, Bent John P, April Max M, Ward Robert F

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To study complications of powered intracapsular tonsillectomy and adenoidectomy (PITA) in pediatric patients with obstructive sleep apnea (OSA).

STUDY

DESIGN

Retrospective chart review and long-term follow-up in office or by telephone interview.

METHODS

We studied 278 patients who underwent PITA between September 2000 and October 2002. Outcome measures were postoperative bleeding, velopharyngeal insufficiency, need for hospital readmission, tonsil regrowth, and return of snoring or sleep apnea symptoms.

RESULTS

All 278 children treated by PITA had immediate resolution of symptoms of OSA. Complications were noted in 11 patients (3.9%). Nine patients (3.2%) experienced tonsil regrowth with snoring, two of whom evolved to a return of OSA that was definitively managed by means of a complete tonsillectomy. Two patients (0.7%) had self-limited bleeding. None of the patients developed persistent velopharyngeal insufficiency or required hospital readmission.

CONCLUSIONS

Microdebrider-assisted PITA is a safe and effective alternative for children otherwise treated with traditional tonsillectomy for symptoms of OSA due to adenotonsillar hypertrophy. This series suggests a 3.9% overall rate of complications, with the most common noted as tonsillar regrowth without recurrence of OSA. Prospective trials with longer follow-up may define higher complication rates.

Для цитирования: Sorin Alexander, Bent John P, April Max M, Ward Robert F. Complications of microdebrider-assisted powered intracapsular tonsillectomy and adenoidectomy.. The Laryngoscope. 2004. DOI: 10.1097/00005537-200402000-00022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.