MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2009.03.039

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2009

Bath and shower effects in the rat parotid gland explain increased relative risk of parotid gland dysfunction after intensity-modulated radiotherapy.

van Luijk Peter, Faber Hette, Schippers Jacobus M, Brandenburg Sytze, Langendijk Johannes A, Meertens Harm, Coppes Robert P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To assess in a rat model whether adding a subtolerance dose in a region adjacent to a high-dose irradiated subvolume of the parotid gland influences its response (bath-and-shower effect).

METHODS AND MATERIALS: Irradiation of the whole, cranial 50%, and/or the caudal 50% of the parotid glands of Wistar rats was performed using 150-MeV protons. To determine suitable (i.e., subtolerance) dose levels for a bath-dose, both whole parotid glands were irradiated with 5 to 25 Gy. Subsequently groups of Wistar rats received 30 Gy to the caudal 50% (shower) and 0 to 10 Gy to the cranial 50% (bath) of both parotid glands. Stimulated saliva flow rate (function) was measured before and up to 240 days after irradiation.

RESULTS

Irradiation of both glands up to a dose of 10 Gy did not result in late loss of function and is thus regarded subtolerance. Addition of a dose bath of 1 to 10 Gy to a high-dose in the caudal 50% of the glands resulted in enhanced function loss.

CONCLUSION

Similar to the spinal cord, the parotid gland demonstrates a bath and shower effect, which may explain the less-than-expected sparing of function after IMRT.

Для цитирования: van Luijk Peter, Faber Hette, Schippers Jacobus M, Brandenburg Sytze, Langendijk Johannes A, Meertens Harm, Coppes Robert P. Bath and shower effects in the rat parotid gland explain increased relative risk of parotid gland dysfunction after intensity-modulated radiotherapy.. International journal of radiation oncology, biology, physics. 2009. DOI: 10.1016/j.ijrobp.2009.03.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.