MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000327526

Медицинская библиотека · Acta cytologica · 2011

Performance of the New INNO-LiPA HPV extra to genotype human papillomavirus in cervical cell specimens.

Galan-Sanchez Fátima, Hernández-Menendez Maite, De Los Rios Hernandez María Angeles, Rodriguez-Iglesias Manuel

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

It was our aim to compare the INNO-LiPA HPV Genotyping Extra (LiPA; Innogenetics) versus the Linear Array test (LA; Roche) in cervical samples.

STUDY

DESIGN

One hundred cervical samples were selected, obtained from a cancer prevention center. All samples were human papillomavirus (HPV) DNA positive by Hybrid Capture 2 HPV test and genotyped by LA HPV genotyping test. All data were analyzed using Cohen's κ tests. κ values ranged from poor, fair, moderate and good to very good agreement strength.

RESULTS

Detection of multiple infection and HPV genotypes per sample was higher by LA than by LiPA (61.5 vs. 52.1 and 2.2 vs. 1.7%, respectively). There were concordant results in 65 samples and compatible results in 33 samples. Only 2 samples were considered as discordant. In 21 samples, additional types were detected by LA, and in 13 samples, additional types were detected by LiPA. Analyzing the κ values, we have found very good agreement for 14 genotypes (6, 16, 26, 31, 33, 35, 45, 51, 52, 53, 58, 66, 68 and 70).

CONCLUSIONS

We considered that the new LiPA is highly comparable with other methods and suitable for clinical and epidemiological studies.

Для цитирования: Galan-Sanchez Fátima, Hernández-Menendez Maite, De Los Rios Hernandez María Angeles, Rodriguez-Iglesias Manuel. Performance of the New INNO-LiPA HPV extra to genotype human papillomavirus in cervical cell specimens.. Acta cytologica. 2011. DOI: 10.1159/000327526.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.