The Tokai journal of experimental and clinical medicine · 2018
Clinical Application of High-pitched Breath Sound in Children with Asthma.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kondo Yoshimi, Nukaga Mariko, Enseki Mayumi, Tabata Hideyuki, Hirai Kota, Kato Masahiko, Mochizuki Hiroyuki
Аннотация
OBJECTIVE: Breath sound parameters have been suggested to be a new biomarker of airway conditions in asthmatic patients. We investigated new breath sound parameters to determine their utility for evaluating asthmatic children.
METHODS: Fifty-seven children (mean age, 9.0 years, 6-16 years) were included in the present study. The new breath sound parameters, the area under the curve (AUC)>1,000 Hz (A1000 [dBm·Hz]) and the ratio of the A1000 to the total AUC at 100 Hz to the highest frequency of the dBm power spectrum (AT) (A1000/AT [%]) were measured before and after β2 agonist inhalation. Spirography and the forced oscillation technique were also used to evaluate all subjects.
RESULTS: The value of A1000 was negatively correlated with the FEV1 (p=0.028). The increase in the ΔFEV1 was correlated with the decrease in the ΔA1000 (p=0.001) and the ΔA1000/AT (p=0.036).
CONCLUSIONS: The A1000 indicates the airway condition, and the ΔA1000 and the ΔA1000/AT well describe the dilatation of the airways. These parameters are useful for the assessment of bronchial reversibility in asthmatic children.
METHODS: Fifty-seven children (mean age, 9.0 years, 6-16 years) were included in the present study. The new breath sound parameters, the area under the curve (AUC)>1,000 Hz (A1000 [dBm·Hz]) and the ratio of the A1000 to the total AUC at 100 Hz to the highest frequency of the dBm power spectrum (AT) (A1000/AT [%]) were measured before and after β2 agonist inhalation. Spirography and the forced oscillation technique were also used to evaluate all subjects.
RESULTS: The value of A1000 was negatively correlated with the FEV1 (p=0.028). The increase in the ΔFEV1 was correlated with the decrease in the ΔA1000 (p=0.001) and the ΔA1000/AT (p=0.036).
CONCLUSIONS: The A1000 indicates the airway condition, and the ΔA1000 and the ΔA1000/AT well describe the dilatation of the airways. These parameters are useful for the assessment of bronchial reversibility in asthmatic children.