MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31557/apjcp.2022.23.9.2973

Медицинская библиотека · Asian Pacific journal of cancer prevention : APJCP · 2022

Estimation of Surface Dose in the Presence of Unwanted Air Gaps under the Bolus in Postmastectomy Radiation Therapy: A Phantom Dosimetric Study.

Dilson Lobo, Challapalli Srinivas, Sourjya Banerjee, Athiyamaan M S, Ramamoorthy Ravichandran, Johan Sunny, Abhishek Krishna

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study is to design and fabricate a thorax phantom with irregularly shaped trapezoidal slots across the left side of the chest wall, allowing for the creation of unwanted air gaps under the bolus.

METHOD: Surface dose (Dsurf) measurements were made with Gaf Chromic EBT3 films at air gaps (0.0, 5.0, 10.0 and 15.0 mm) under gel bolus of thickness (5.0 mm & 10.0 mm), for 3DCRT technique (2 and 3 field) with clinical 6 MV photon beam under uniform and non-uniform air gap condition. The obtained values were compared with TPS estimated ones.

RESULTS

In the presence of 15.0 mm uniform air gap, the mean estimated and measured Dsurf values with two and three field techniques decreased by 14.0 % to 15.2% and 14.7% to 17.4% under 5.0 mm and 10.0 mm bolus applications respectively. In presence of non-uniform air gap condition, the effect on Dsurf was minimal (3 to 3.5%) compared with the uniform air gap condition.

CONCLUSIONS

Based on the study's findings, it is recommended that when using bolus in clinical radiotherapy applications, special care be taken to avoid unwanted air gaps under the bolus in order to achieve a uniform surface dose across the treatment region, where a customized 3D printed bolus may be a better option.

Для цитирования: Dilson Lobo, Challapalli Srinivas, Sourjya Banerjee, Athiyamaan M S, Ramamoorthy Ravichandran, Johan Sunny, Abhishek Krishna. Estimation of Surface Dose in the Presence of Unwanted Air Gaps under the Bolus in Postmastectomy Radiation Therapy: A Phantom Dosimetric Study.. Asian Pacific journal of cancer prevention : APJCP. 2022. DOI: 10.31557/apjcp.2022.23.9.2973.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.