BACKGROUND

Cardiovascular magnetic resonance (CMR) imaging during supine exercise at (sub)maximal oxygen consumption (VO2 ) offers unique diagnostic insights. However, maximal VO2 is not achievable in the supine position and standardizing submaximal exercise intensities remains challenging. Using heart rate or workload could be a viable option to translate VO2 -based submaximal exercise intensities.

AIM: To translate submaximal exercise intensities upright cycling exercise (UCE) to supine push-pull exercise (SPPE), by comparing heart rate or workload determined during UCE, with heart rate and workload during SPPE at similar exercise intensities.

METHODS AND

RESULTS

Sixteen healthy young adults (20.4 ± 2.2 years; 8 female) underwent cardiopulmonary UCE and SPPE testing [mean ± standard deviation maximal VO2 : 3.2 ± 0.6 vs. 5 ± 0.3 L min-1 , p < 0.001 and median (interquartile range) of the maximum workload: 310 (244, 361) vs. 98 (98, 100), p < 0.001, respectively]. Heart rate at 40% and 60% of maximal VO2 , as determined by UCE, showed low bias (-3 and 0 bpm, respectively) and wide limits of agreement (±26 and ±28 bpm, respectively), in Bland-Altman analysis. VO2 /Workload relation was exponential and less efficient during SPPE compared to UCE. Generalized estimated equation analysis predicted model-based mean workload during SPPE, with acceptable 95% confidence interval.

CONCLUSION

Heart rate during UCE at submaximal exercise intensities can reasonably well be used to for SPPE in healthy subjects. Using workload, an ergometer specific, model-based mean can be used to determine exercise intensities during SPPE. Individual variations in response to posture and movement change are high. During clinical interpretation of exercise CMR, individual exercise intensity has to be considered.

Для цитирования: Steenhorst Jarno J, Hirsch Alexander, van den Berg Linda E M, Kamphuis Lieke S, Merkus Daphne, Boersma Eric, Helbing Willem A. Standardizing submaximal exercise intensities for use of supine push-pull exercise during cardiovascular magnetic resonance.. Clinical physiology and functional imaging. 2022. DOI: 10.1111/cpf.12784.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.