Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2018
Performance of Molecular Lymphosonography for Detection and Quantification of Metastatic Involvement in Sentinel Lymph Nodes.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nam Kibo, Stapp Robert, Liu Ji-Bin, Stanczak Maria, Forsberg Flemming, O'Kane Patrick L, Lin Zhou, Zhu Ziyin, Li Jingzhi, Solomides Charalambos C, Eisenbrey John R, Lyshchik Andrej
Аннотация
OBJECTIVES: To assess the performance of molecular lymphosonography with dual-targeted microbubbles in detecting and quantifying the metastatic involvement in sentinel lymph nodes (SLNs) using a swine melanoma model.
METHODS: Targeted microbubbles were labeled with P-selectin and αV β3 -integrin antibodies. Control microbubbles were labeled with immunoglobulin G antibodies. First lymphosonography with Sonazoid (GE Healthcare, Oslo, Norway) was used to identify SLNs. Then dual-targeted and control microbubbles were injected intravenously to detect and quantify metastatic disease in the SLNs. Distant non-SLNs were imaged as benign controls. All evaluated lymph nodes (LNs) were surgically removed, and metastatic involvement was characterized by a histopathologic analysis. Two radiologists blinded to histopathologic results assessed the baseline B-mode images of LNs, and the results were compared to the histologic reference standard. The mean intensities of targeted and control microbubbles within the examined LNs were measured and compared to the LN histologic results.
RESULTS: Thirty-five SLNs and 34 non-SLNs from 13 Sinclair swine were included in this study. Twenty-one SLNs (62%) were malignant, whereas 100% of non-SLNs were benign. The sensitivity of B-mode imaging for metastatic LN diagnosis for both readers was relatively high (90% and 71%), but the specificity was very poor (50% and 58%). The sensitivity and specificity of molecular lymphosonography for metastatic LN detection were 91% and 67%, respectively. The mean intensities from dual-targeted microbubbles correlated well with the degree of metastatic LN involvement (r = 0.6; P < 0.001).
CONCLUSIONS: Molecular lymphosonography can increase the specificity of metastatic LN detection and provide a measure to quantify the degree of metastatic involvement.
METHODS: Targeted microbubbles were labeled with P-selectin and αV β3 -integrin antibodies. Control microbubbles were labeled with immunoglobulin G antibodies. First lymphosonography with Sonazoid (GE Healthcare, Oslo, Norway) was used to identify SLNs. Then dual-targeted and control microbubbles were injected intravenously to detect and quantify metastatic disease in the SLNs. Distant non-SLNs were imaged as benign controls. All evaluated lymph nodes (LNs) were surgically removed, and metastatic involvement was characterized by a histopathologic analysis. Two radiologists blinded to histopathologic results assessed the baseline B-mode images of LNs, and the results were compared to the histologic reference standard. The mean intensities of targeted and control microbubbles within the examined LNs were measured and compared to the LN histologic results.
RESULTS: Thirty-five SLNs and 34 non-SLNs from 13 Sinclair swine were included in this study. Twenty-one SLNs (62%) were malignant, whereas 100% of non-SLNs were benign. The sensitivity of B-mode imaging for metastatic LN diagnosis for both readers was relatively high (90% and 71%), but the specificity was very poor (50% and 58%). The sensitivity and specificity of molecular lymphosonography for metastatic LN detection were 91% and 67%, respectively. The mean intensities from dual-targeted microbubbles correlated well with the degree of metastatic LN involvement (r = 0.6; P < 0.001).
CONCLUSIONS: Molecular lymphosonography can increase the specificity of metastatic LN detection and provide a measure to quantify the degree of metastatic involvement.