A model-based patient selection tool to identify who may be at risk of exceeding dose tolerances during pancreatic SBRT.

Magallon-Baro Alba, Granton Patrick V, Milder Maaike T W, Loi Mauro, Zolnay Andras G, Nuyttens Joost J, Hoogeman Mischa S

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Locally advanced pancreatic cancer (LAPC) patients are prone to experience daily anatomical variations, which can lead to additional doses in organs-at-risk (OAR) during SBRT. A patient selection tool was developed to identify who may be at risk of exceeding dose tolerances, by quantifying the dosimetric impact of daily variations using an OAR motion model.

MATERIALS AND

METHODS

The study included 133 CT scans from 35 LAPC patients. By following a leave-one-out approach, an OAR motion model trained with the remaining 34 subjects variations was used to simulate organ deformations on the left-out patient planning CT anatomy. Dose-volume histograms obtained from planned doses sampled on simulated organs resulted in the probability of exceeding OAR dose-constraints due to anatomical variations. Simulated probabilities were clustered with a threshold per organ according to clinical observations. If the prediction of at least one OAR was above the established thresholds, the patient was classified as being at risk.

RESULTS

Clinically, in 20/35 patients at least one OAR exceeded dose-constraints in the daily CTs. The model-based prediction had an accuracy of 89%, 71%, 91% in estimating the risk of exceeding dose tolerances for the duodenum, stomach and bowel, respectively. By combining the three predictions, our approach resulted in a correct patient classification for 29/35 patients (83%) when compared with clinical observations.

CONCLUSIONS

Our model-based patient selection tool is able to predict who might be at risk of exceeding dose-constraints during SBRT. It is a promising tool to tailor LAPC treatments, e.g. by employing online adaptive SBRT; and hence, to minimize toxicity of patients being at risk.

Для цитирования: Magallon-Baro Alba, Granton Patrick V, Milder Maaike T W, Loi Mauro, Zolnay Andras G, Nuyttens Joost J, Hoogeman Mischa S. A model-based patient selection tool to identify who may be at risk of exceeding dose tolerances during pancreatic SBRT.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2019. DOI: 10.1016/j.radonc.2019.09.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.