MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.2493072045

Медицинская библиотека · Radiology · 2008

Parotid gland tumors: can addition of diffusion-weighted MR imaging to dynamic contrast-enhanced MR imaging improve diagnostic accuracy in characterization?

Yabuuchi Hidetake, Matsuo Yoshio, Kamitani Takeshi, Setoguchi Taro, Okafuji Takashi, Soeda Hiroyasu, Sakai Shuji, Hatakenaka Masamitsu, Nakashima Torahiko, Oda Yoshinao, Honda Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the value of adding diffusion-weighted (DW) magnetic resonance (MR) imaging to dynamic contrast material-enhanced MR imaging when distinguishing between benign and malignant parotid tumors.

MATERIALS AND

METHODS

This retrospective study was approved by the institutional review board, and the informed consent requirement was waived. The authors analyzed MR images of 50 lesions (36 benign, 14 malignant) in 47 patients. DW MR imaging and dynamic contrast-enhanced MR imaging were performed in all patients. Time-intensity curve (TIC) patterns were categorized as follows: type A, time to peak was more than 120 seconds; type B, time to peak was 120 seconds or less with high washout ratio (> or = 30%); type C, time to peak was 120 seconds or less with low washout ratio (< 30%); and type D, flat. The apparent diffusion coefficient (ADC) values were measured on DW MR images. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated for type A, B, and D tumors regarded as benign and for type C tumors regarded as malignant. On the basis of DW MR imaging results, ADC threshold values between pleomorphic adenomas and carcinomas and between Warthin tumors and carcinomas were selected. Diagnostic accuracy was compared before and after modification diagnosis referring to the ADC value obtained with the McNemar test. P < .05 was considered to indicate a significant difference.

RESULTS

ADC threshold values were 1.4 x 10(-3) mm(2)/sec between pleomorphic adenomas and carcinomas and 1.0 x 10(-3) mm(2)/sec between Warthin tumors and carcinomas. Accuracy (82% vs 94%) and positive predictive value (67% vs 92%) significantly improved with the addition of ADC values in the evaluation of patients with type B or C tumors.

CONCLUSION

A persistent or flat TIC pattern on dynamic contrast-enhanced MR images indicates benign disease, but there is added value from including the ADC value in the evaluation of tumors that show a plateau or washout TIC pattern.

Для цитирования: Yabuuchi Hidetake, Matsuo Yoshio, Kamitani Takeshi, Setoguchi Taro, Okafuji Takashi, Soeda Hiroyasu, Sakai Shuji, Hatakenaka Masamitsu, Nakashima Torahiko, Oda Yoshinao, Honda Hiroshi. Parotid gland tumors: can addition of diffusion-weighted MR imaging to dynamic contrast-enhanced MR imaging improve diagnostic accuracy in characterization?. Radiology. 2008. DOI: 10.1148/radiol.2493072045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.