MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20140736

Медицинская библиотека · The British journal of radiology · 2015

Volumetric-modulated arc stereotactic body radiotherapy for prostate cancer: dosimetric impact of an increased near-maximum target dose and of a rectal spacer.

Ruggieri Ruggero, Naccarato Stefania, Stavrev Pavel, Stavreva Nadejda, Fersino Sergio, Giaj Levra Niccolò, Mazzola Rosario, Mancosu Pietro, Scorsetti Marta, Alongi Filippo

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

In volumetric-modulated arc therapy (VMAT) prostate stereotactic body radiotherapy (SBRT), dose coverage of the planning target volume (PTV) becomes challenging when the sparing of rectum, bladder and urethra is strictly pursued. Our current 35-Gy-in-five-fraction plans only assure 33.2 Gy to ≥95% PTV ([Formula: see text] ≥ 95%). Looking for an improved [Formula: see text], increased near-maximum target dose (D2%) and prostate-rectum spacer insertion were tested.

METHODS

For 11 patients, two VMAT plans, with D2% ≤ 37.5 Gy (Hom) or D2% ≤ 40.2 Gy (Het), on each of two CT studies, before or after spacer insertion, were computed. All plans assured [Formula: see text] ≥95%, and <1 cm(3) of rectum, bladder and urethra receiving ≥35 Gy. By hypothesis testing, several dose-volume metrics for target coverage and rectal sparing were compared across the four groups of plans. The impact of spacer insertion on the fractions of rectum receiving more than 18, 28 and 32 Gy ([Formula: see text]) was further tested by linear correlation analysis.

RESULTS

By hypothesis testing, the increased D2% was associated with improvements in target coverage, whereas spacer insertion was associated with improvements in both target coverage and rectal [Formula: see text]. By linear correlation analysis, spacer insertion was related to the reductions in rectal [Formula: see text] for X ≥ 28 Gy.

CONCLUSION

A slightly increased D2% or the use of spacer insertion was each able to improve [Formula: see text]. Their combined use assured [Formula: see text] ≥ 98% to all our patients. Spacer insertion was further causative for improvements in rectal sparing.

ADVANCES IN KNOWLEDGE: For VMAT plans in prostate SBRT, the distinct dosimetric usefulness of increased D2% and of the use of spacer insertion were validated in terms of target coverage and rectal sparing.

Для цитирования: Ruggieri Ruggero, Naccarato Stefania, Stavrev Pavel, Stavreva Nadejda, Fersino Sergio, Giaj Levra Niccolò, Mazzola Rosario, Mancosu Pietro, Scorsetti Marta, Alongi Filippo. Volumetric-modulated arc stereotactic body radiotherapy for prostate cancer: dosimetric impact of an increased near-maximum target dose and of a rectal spacer.. The British journal of radiology. 2015. DOI: 10.1259/bjr.20140736.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.