MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1549-8719.2012.00182.x

Медицинская библиотека · Microcirculation (New York, N.Y. : 1994) · 2012

Feasibility of conjunctival hemodynamic measurements in rabbits: reproducibility, validity, and response to acute hypotension.

Gaynes Bruce, Teng Pang-Yu, Wanek Justin, Shahidi Mahnaz

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the feasibility of conjunctival hemodynamic measurements based on assessment of reproducibility, validity, and response to acute hypotension.

METHODS

Image sequences of the conjunctival microvasculature of rabbits were captured using a slit lamp biomicroscope under a steady-state condition, after topical administration of phenylephrine, and after intravenous administration of esmolol. Venous hemodynamic parameters (diameter, blood velocity, blood flow, and wall shear stress) were derived.

RESULTS

Conjunctival venous diameters ranged from 9 to 34 μm and blood velocities ranged from 0.08 to 0.95 mm/s. Coefficients of variation of venous diameter and blood velocity measurements were, on average, 6% and 14%, respectively. Automated and manual measurements of venous diameter and velocity were highly correlated (R = 0.97; p < 0.001; n = 16). With phenylephrine administration, diameter and velocity were reduced by 21% and 69%, respectively. Following esmolol administration, blood pressure was reduced with a concomitant decrease in velocity, followed by recovery to baseline. Venous blood velocity, flow, and WSS were correlated with blood pressure (R ≥ 0.52; p ≤ 0.01).

CONCLUSIONS

The feasibility of quantifying alterations in microvascular hemodynamics in the bulbar conjunctiva was established. The method is of potential value in evaluating microcirculatory hemodynamics related to cardiovascular function.

Для цитирования: Gaynes Bruce, Teng Pang-Yu, Wanek Justin, Shahidi Mahnaz. Feasibility of conjunctival hemodynamic measurements in rabbits: reproducibility, validity, and response to acute hypotension.. Microcirculation (New York, N.Y. : 1994). 2012. DOI: 10.1111/j.1549-8719.2012.00182.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.