MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2353/jmoldx.2010.100045

Медицинская библиотека · The Journal of molecular diagnostics : JMD · 2010

HPV genotype detection using hybrid capture sample preparation combined with whole genome amplification and multiplex detection with Luminex XMAP.

Lowe Brian, Kobayashi Lori, Lorincz Attila, Mallonee Rick, O'Neil Dominic, Thai Ha, Nazarenko Irina

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Infection with a high-risk carcinogenic type of human papillomavirus (HPV) is necessary for the development of cervical cancer. The digene HC2 HPV Test (HC2) is an important screening tool but lacks genotyping capability. To address this issue, we developed an assay for the rapid genotyping of HPV in cervical specimens. The three steps of this assay include Hybrid Capture target enrichment, whole-genome amplification, and Luminex XMAP detection. The assay includes the simultaneous detection of two genomic regions from each of 17 high-risk and two low-risk HPV types most associated with disease. The assay performance was tested on HPV plasmids as well as clinical specimens. An analytical limit of detection of 100 copies or less was demonstrated for linear, circular, and integrated HPV DNA. This finding is at least 1 log lower than the HC2 assay limit of detection. There was no cross-reactivity among the HPV types up to 1,000,000 copies. There was also no substantial assay interference from substances in cervical specimens. Although the clinical performance of the assay was not formally tested, the assay had good agreement (Cohen's kappa equal to 0.72) with both a PCR-based HPV genotyping assay (n = 131) and the HC2 assay (n = 502) using representative cervical specimens. This assay may be easy to automate and could be applied for the detection of other targets in future studies.

Для цитирования: Lowe Brian, Kobayashi Lori, Lorincz Attila, Mallonee Rick, O'Neil Dominic, Thai Ha, Nazarenko Irina. HPV genotype detection using hybrid capture sample preparation combined with whole genome amplification and multiplex detection with Luminex XMAP.. The Journal of molecular diagnostics : JMD. 2010. DOI: 10.2353/jmoldx.2010.100045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.