MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aap.0b013e3181c75a8b

Медицинская библиотека · Regional anesthesia and pain medicine · 2010

In-plane ultrasound-guided thoracic paravertebral block: a preliminary report of 36 cases with radiologic confirmation of catheter position.

Renes Steven H, Bruhn Jörgen, Gielen Mathieu J, Scheffer Gert J, van Geffen Geert J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Thoracic paravertebral block (TPVB) can be used for unilateral surgical procedures. Modifications of the classic approach have been proposed to minimize the risk of pleural puncture. In this study, we evaluated the feasibility and success rate of a transverse in-plane ultrasound (US)-guided TPVB with radiologic confirmation of catheter position.

METHODS

A total of 36 patients scheduled for unilateral surgery with a TPVB catheter were included in this prospective study. Ultrasonographically, the transverse process of the thoracic vertebra and rib were identified at the appropriate thoracic level. The transducer was moved cranially until an intercostal US view was obtained, indicated by visualization of the parietal pleura. An in-plane needle insertion approach from lateral to medial was used, and a total of 20 mL ropivacaine 0.75% was injected through the needle and a subsequently threaded catheter, while the spread of local anesthetic was observed. Sensory spread of the block was evaluated by loss of cold sensation in the dermatomes. Catheter position was radiologically evaluated with radiopaque dye.

RESULTS

Block success rate was 100%. In all patients, correct radiologic thoracic paravertebral catheter position was confirmed; 1 patient also showed additional epidural spread. The median number of total dermatomal segments with loss of cold sensation was 6. No pneumothorax or contralateral loss of cold sensation occurred.

CONCLUSION

An in-plane transverse US-guided TPVB using the described technique is feasible and has a high success rate. In all patients, correct catheter position in the thoracic paravertebral space was radiologically confirmed.

Для цитирования: Renes Steven H, Bruhn Jörgen, Gielen Mathieu J, Scheffer Gert J, van Geffen Geert J. In-plane ultrasound-guided thoracic paravertebral block: a preliminary report of 36 cases with radiologic confirmation of catheter position.. Regional anesthesia and pain medicine. 2010. DOI: 10.1097/aap.0b013e3181c75a8b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.