DOI 10.1177/15330338221078464

Медицинская библиотека · Technology in cancer research & treatment · 2022

Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases.

Han Min Cheol, Kim Jihun, Hong Chae-Seon, Chang Kyung Hwan, Han Su Chul, Park Kwangwoo, Kim Dong Wook, Kim Hojin, Chang Jee Suk, Kim Jina, Kye Sunsuk, Park Ryeong Hwang, Chung Yoonsun, Kim Jin Sung

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Purpose: Various deformable image registration (DIR) methods have been used to evaluate organ deformations in 4-dimensional computed tomography (4D CT) images scanned during the respiratory motions of a patient. This study assesses the performance of 10 DIR algorithms using 4D CT images of 5 patients with fiducial markers (FMs) implanted during the postoperative radiosurgery of multiple lung metastases.

Methods

To evaluate DIR algorithms, 4D CT images of 5 patients were used, and ground-truths of FMs and tumors were generated by physicians based on their medical expertise. The positions of FMs and tumors in each 4D CT phase image were determined using 10 DIR algorithms, and the deformed results were compared with ground-truth data.

Results

The target registration errors (TREs) between the FM positions estimated by optical flow algorithms and the ground-truth ranged from 1.82 ± 1.05 to 1.98 ± 1.17 mm, which is within the uncertainty of the ground-truth position. Two algorithm groups, namely, optical flow and demons, were used to estimate tumor positions with TREs ranging from 1.29 ± 1.21 to 1.78 ± 1.75 mm. With respect to the deformed position for tumors, for the 2 DIR algorithm groups, the maximum differences of the deformed positions for gross tumor volume tracking were approximately 4.55 to 7.55 times higher than the mean differences. Errors caused by the aforementioned difference in the Hounsfield unit values were also observed.

Conclusions

We quantitatively evaluated 10 DIR algorithms using 4D CT images of 5 patients and compared the results with ground-truth data. The optical flow algorithms showed reasonable FM-tracking results in patient 4D CT images. The iterative optical flow method delivered the best performance in this study. With respect to the tumor volume, the optical flow and demons algorithms delivered the best performance.

Для цитирования: Han Min Cheol, Kim Jihun, Hong Chae-Seon, Chang Kyung Hwan, Han Su Chul, Park Kwangwoo, Kim Dong Wook, Kim Hojin, Chang Jee Suk, Kim Jina, Kye Sunsuk, Park Ryeong Hwang, Chung Yoonsun, Kim Jin Sung. Performance Evaluation of Deformable Image Registration Algorithms Using Computed Tomography of Multiple Lung Metastases.. Technology in cancer research & treatment. 2022. DOI: 10.1177/15330338221078464.