MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jcbfm.1990.2

Медицинская библиотека · Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 1990

A new method to measure brain serotonin synthesis in vivo. II. A practical autoradiographic method tested in normal and lithium-treated rats.

Nagahiro S, Takada A, Diksic M, Sourkes T L, Missala K, Yamamoto Y L

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We describe here a practical autoradiographic method to estimate the rate of serotonin synthesis in brain. A two-time point method (60 and 150 min after injection of alpha-[14C]methyl-L-tryptophan) was first evaluated in 14 normal rats (7 at each time point). After this the method was tested in lithium-treated rats. In normal rats the rate of serotonin synthesis measured by the two-time point method generally correlated with known concentrations of tryptophan hydroxylase. The rate of synthesis in lithium-treated rats was compared with that in sham-treated rats (NaCl treatment). The results showed a significant increase in the synthesis rate in some cerebral structures. The greatest increases in the serotonin synthesis rate, attributable to the lithium treatment, were observed in the parietal cortex (52%) and caudate nucleus (47%). This is the first investigation to demonstrate, with autoradiographic resolution (approximately 100 microns), the differential changes in the rate of serotonin synthesis in the brain. Lithium had no significant effect on the rate of synthesis in the pineal gland.

Для цитирования: Nagahiro S, Takada A, Diksic M, Sourkes T L, Missala K, Yamamoto Y L. A new method to measure brain serotonin synthesis in vivo. II. A practical autoradiographic method tested in normal and lithium-treated rats.. Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism. 1990. DOI: 10.1038/jcbfm.1990.2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.