BACKGROUND

Daily image-guided radiotherapy (IGRT) can contribute to cover extended body volumes with low radiation dose. The effect of additional imaging dose on secondary cancer development is modelled for a collective of children with Morbus Hodgkin.

METHODS

Eleven radiotherapy treatment plans from pediatric patients with Hodgkin's lymphoma were retrospectively analyzed, including imaging dose from scenarios using different energies (kV/MV) and planar/cone-beam computed tomography (CBCT) techniques. In addition to assessing the effect of imaging dose on organs at risk, the excess average risk (EAR) for developing a secondary carcinoma of the lung or breast was modelled.

RESULTS

Although the variability between the patients is relatively large due to the different target volumes, the additional EAR due to imaging can be consistently determined. For daily 6MV CBCT, the EAR for developing a secondary cancer at age 50 is over 3 cases per 104 PY (patient-years) for the female breast and 0.7-0.8 per 104 PY for the lungs. This can be decreased by using only planar images (< 1 per 104 PY for the breast and 0.1 for the lungs). Similar values are achieved by daily 360° kV CBCT (0.44-0.57 per 104 PY for the breast and 0.08 per 104 PY for the lungs), which is again reduced for daily 200° kV CBCT (0.02 per 104 PY for the lungs and 0.07-0.08 per 104 PY for the breast). These values increase if an older attained age is considered (e.g., for 70 years, by a factor of four for the lungs).

CONCLUSIONS

Daily imaging can be performed with an additional secondary cancer risk of less than 1 per 104 PY if kV CBCT is applied. If MV modalities must be chosen, a similar EAR can be achieved with planar images. A further reduction in risk is possible if the imaging geometry allows for sparing of the breast by a partial rotation underneath the patient.

Для цитирования: Dzierma Yvonne, Mikulla Katharina, Richter Patrick, Bell Katharina, Melchior Patrick, Nuesken Frank, Rübe Christian. Imaging dose and secondary cancer risk in image-guided radiotherapy of pediatric patients.. Radiation oncology (London, England). 2018. DOI: 10.1186/s13014-018-1109-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.