MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/acm2.13809

Медицинская библиотека · Journal of applied clinical medical physics · 2022

Contour similarity and its implication on inverse prostate SBRT treatment planning.

Yan Chenyu, Guo Bingqi, Tendulkar Rahul, Xia Ping

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Success of auto-segmentation is measured by the similarity between auto and manual contours that is often quantified by Dice coefficient (DC). The dosimetric impact of contour variability on inverse planning has been rarely reported. The main aim of this study is to investigate whether automatically generated organs-at-risk (OARs) could be used in inverse prostate stereotactic body radiation therapy (SBRT) planning and whether the dosimetric parameters are still clinically acceptable after radiation oncologists modify the OARs.

METHODS AND MATERIALS: Planning computed tomography images from 10 patients treated with SBRT for prostate cancer were selected and automatically segmented by commercially available atlas-based software. The automatically generated OAR contours were compared with the manually drawn contours. Two volumetric modulated arc therapy (VMAT) plans, autoRec-VMAT (where only automatically generated rectums were used in optimization) and autoAll-VMAT (where automatically generated OARs were used in inverse optimization) were generated. Dosimetric parameters based on the manually drawn PTV and OARs were compared with the clinically approved plans.

RESULTS

The DCs for the rectum contours varied from 0.55 to 0.74 with a mean value of 0.665. Differences of D95 of the PTV between autoRec-VMAT and manu-VMAT plans varied from 0.03% to -2.85% with a mean value of -0.64%. Differences of D0.03cc of manual rectum between the two plans varied from -0.86% to 9.94% with a mean value of 2.71%. D95 of PTV between autoAll-VMAT and manu-VMAT plans varied from 0.28% to -2.9% with a mean value -0.83%. Differences of D0.03cc of manual rectum between the two plans varied from -0.76% to 6.72% with a mean value of 2.62%.

CONCLUSION

Our study implies that it is possible to use unedited automatically generated OARs to perform initial inverse prostate SBRT planning. After radiation oncologists modify/approve the OARs, the plan qualities based on the manually drawn OARs are still clinically acceptable, and a re-optimization may not be needed.

Для цитирования: Yan Chenyu, Guo Bingqi, Tendulkar Rahul, Xia Ping. Contour similarity and its implication on inverse prostate SBRT treatment planning.. Journal of applied clinical medical physics. 2022. DOI: 10.1002/acm2.13809.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.