MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-022-19498-6

Медицинская библиотека · Scientific reports · 2022

Multi-institution model (big model) versus single-institution model of knowledge-based volumetric modulated arc therapy (VMAT) planning for prostate cancer.

Fukunaga Jun-Ichi, Tamura Mikoto, Ueda Yoshihiro, Kamima Tatsuya, Shimizu Yumiko, Muraki Yuta, Nakamatsu Kiyoshi, Monzen Hajime

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We established a multi-institution model (big model) of knowledge-based treatment planning with over 500 treatment plans from five institutions in volumetric modulated arc therapy (VMAT) for prostate cancer. This study aimed to clarify the efficacy of using a large number of registered treatment plans for sharing the big model. The big model was created with 561 clinically approved VMAT plans for prostate cancer from five institutions (A: 150, B: 153, C: 49, D: 60, and E: 149) with different planning strategies. The dosimetric parameters of planning target volume (PTV), rectum, and bladder for two validation VMAT plans generated with the big model were compared with those from each institutional model (single-institution model). The goodness-of-fit of regression lines (R2 and χ2 values) and ratios of the outliers of Cook's distance (CD) > 4.0, modified Z-score (mZ) > 3.5, studentized residual (SR) > 3.0, and areal difference of estimate (dA) > 3.0 for regression scatter plots in the big model and single-institution model were also evaluated. The mean ± standard deviation (SD) of dosimetric parameters were as follows (big model vs. single-institution model): 79.0 ± 1.6 vs. 78.7 ± 0.5 (D50) and 0.13 ± 0.06 vs. 0.13 ± 0.07 (Homogeneity Index) for the PTV; 6.6 ± 4.0 vs. 8.4 ± 3.6 (V90) and 32.4 ± 3.8 vs. 46.6 ± 15.4 (V50) for the rectum; and 13.8 ± 1.8 vs. 13.3 ± 4.3 (V90) and 39.9 ± 2.0 vs. 38.4 ± 5.2 (V50) for the bladder. The R2 values in the big model were 0.251 and 0.755 for rectum and bladder, respectively, which were comparable to those from each institution model. The respective χ2 values in the big model were 1.009 and 1.002, which were closer to 1.0 than those from each institution model. The ratios of the outliers in the big model were also comparable to those from each institution model. The big model could generate a comparable VMAT plan quality compared with each single-institution model and therefore could possibly be shared with other institutions.

Для цитирования: Fukunaga Jun-Ichi, Tamura Mikoto, Ueda Yoshihiro, Kamima Tatsuya, Shimizu Yumiko, Muraki Yuta, Nakamatsu Kiyoshi, Monzen Hajime. Multi-institution model (big model) versus single-institution model of knowledge-based volumetric modulated arc therapy (VMAT) planning for prostate cancer.. Scientific reports. 2022. DOI: 10.1038/s41598-022-19498-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.