Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2023

Universal evaluation of MLC models in treatment planning systems based on a common set of dynamic tests.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Saez Jordi, Bar-Deroma Raquel, Bogaert Evelien, Cayez Romain, Chow Tom, Clark Catharine H, Esposito Marco, Feygelman Vladimir, Monti Angelo F, Garcia-Miguel Julia, Gershkevitsh Eduard, Goossens Jo, Herrero Carmen, Hussein Mohammad, Khamphan Catherine, Kierkels Roel G J, Lechner Wolfgang, Lemire Matthieu, Nevelsky Alexander, Nguyen Daniel, Paganini Lucia, Pasler Marlies, Fernando Pérez Azorín José, Ramos Garcia Luis Isaac, Russo Serenella, Shakeshaft John, Vieillevigne Laure, Hernandez Victor

Аннотация

PURPOSE: To demonstrate the feasibility of characterising MLCs and MLC models implemented in TPSs using a common set of dynamic beams.

MATERIALS AND METHODS: A set of tests containing synchronous (SG) and asynchronous sweeping gaps (aSG) was distributed among twenty-five participating centres. Doses were measured with a Farmer-type ion chamber and computed in TPSs, which provided a dosimetric characterisation of the leaf tip, tongue-and-groove, and MLC transmission of each MLC, as well as an assessment of the MLC model in each TPS. Five MLC types and four TPSs were evaluated, covering the most frequent combinations used in radiotherapy departments.

RESULTS: Measured differences within each MLC type were minimal, while large differences were found between MLC models implemented in clinical TPSs. This resulted in some concerning discrepancies, especially for the HD120 and Agility MLCs, for which differences between measured and calculated doses for some MLC-TPS combinations exceeded 10%. These large differences were particularly evident for small gap sizes (5 and 10 mm), as well as for larger gaps in the presence of tongue-and-groove effects. A much better agreement was found for the Millennium120 and Halcyon MLCs, differences being within ± 5% and ± 2.5%, respectively.

CONCLUSIONS: The feasibility of using a common set of tests to assess MLC models in TPSs was demonstrated. Measurements within MLC types were very similar, but TPS dose calculations showed large variations. Standardisation of the MLC configuration in TPSs is necessary. The proposed procedure can be readily applied in radiotherapy departments and can be a valuable tool in IMRT and credentialing audits.